Operating Instructions Bus Module
MBM-PN-..-MLI-… (PROFINET)
42
(translation of the original operating instructions) MAN20001572-01-07/22
13.7. Transponder errors
Err
or code
Err
or designation
Meaning
Err
or category
Err
or behavior
Tr
oubleshooting
Corr
esponding err
or/
status bit
LED displays
Interlocking/locking module
POWER
STAT
E
LOCK
DIA
SLOT 1
SLOT 2
0x42
Invalid handle
module detected
Handle module is
not valid or handle
module is faulty.
Transponder
error
Latching
Restart teach-in operation. If
the error persists, contact our
support team.
LM_E_G
3x
0x25
Disabled actuator
detected
Already taught-
in but disabled
actuator has been
detected.
Transponder
error
Latching
Repeat teach-in operation with
a new handle module or use
taught-in handle module if a
teach-in operation was not
intended.
LM_E_G
3x
13.8. Environment errors
MBM
Err
or code
Err
or designation
Meaning
Err
or category
Err
or behavior
Tr
oubleshooting
Corr
esponding err
or/
status bit
LED displays
Bus module
LINK 1 / LINK 2
ACT 1 / ACT 2
SF
BF
DIA
US1
MAINT
PS
0x60
Supply voltage
too high
Overvoltage
Environ-
ment
error
Reset-
table/
latching
Decrease supply
voltage. Pay attention
to technical data.
BM_E_G
Long
On
5x
rd
0x61
Supply voltage
too low
Low voltage
Environ-
ment
error
Resetta-
ble
Increase supply
voltage or check
system topology. Pay
attention to technical
data and max.
number of modules/
submodules. Possibly
excessively long
cables.