Operating Instructions Bus Module
MBM-PN-..-MLI-… (PROFINET)
20
(translation of the original operating instructions) MAN20001572-01-07/22
10.4. Connecting modules
Modules can either be connected together directly or using cables (see
).
Each module has a top and a bottom connection. You can use either the bottom or the top connection or both if the module
is between two other modules.
The bottom module connector is already integrated. To use the top connection, change its position. If you want to use both
connections, you must order a corresponding module connector. Use only the module connectors intended to interconnect
the modules (see
Table 2: Overview of module connectors
). The maximum cable length for a line must not exceed 40 m.
156718
157025
next module
direct plug
blind plug
stacklight
M12, 5-pin,
male
M12, 5-pin,
female
157024
MGB2-L...
MCM-...
direct plug
cable connect
157028
157029
stacklight
next module
cable connect
(M12, 5-pin,
female)
(M12, 8-pin,
female)
156718
157025
next module
direct plug
blind plug
157028
next module
cable connect
(M12, 5-pin,
female)
161345
Fig. 2:
Connecting modules
Table 2: Overview of module connectors
Function
Order no.
Included?
Module connector M12, 5-pin, plug
157024
1x *
Blanking cover
156718
1x *
Set with sealing caps for unused connections
156739
Yes
Module connector, 5-pin socket, for the direct connection of a further module
157025
No, must be ordered separately
Module connector M12, 5-pin socket, for the connection of a further module via a
connecting cable
157028
Module connector M12, 5-pin socket, for the connection of a stack light
161345
Module connector M12, 8-pin socket, for the connection of a stack light
157029
Connecting cable M12, 5-pin
See catalog or www.euchner.com
Connecting cable M12, 8-pin
* Not for MGB2-…-Y0000-…