Operating Instructions Bus Module
MBM-EC-..-MLI-… (EtherCAT)
50
(translation of the original operating instructions) 2540772-01-11/21
13.7. Transponder errors
Err
or code
Err
or designation
Meaning
Err
or category
Err
or behavior
Tr
oubleshooting
Corr
esponding err
or/status
bit
LED displays
Interlocking/locking module
POWER
STAT
E
LOCK
DIA
SLOT 1
SLOT 2
0x42
Invalid handle
module detected
Handle module is
not valid or handle
module is faulty.
Transponder
errors
Latching
Restart teach-in operation. If
the error persists, contact our
support team.
LM_E_G
3x
0x25
Disabled actuator
detected
Already taught
in but disabled
actuator has been
detected.
Transponder
errors
Latching
Repeat teach-in operation with
a new handle module or use
taught-in handle module if a
teach-in operation was not
intended.
LM_E_G
3x
13.8. Environment errors
MBM
Err
or code
Err
or designation
Meaning
Err
or category
Err
or behavior
Tr
oubleshooting
Corr
esponding err
or/status
bit
LED displays
Bus module
L/A IN
EC ST
AT
L/A OUT
FSoE
DIA
MAINT
SF
POWER
0x60
Supply voltage
too high
Overvoltage
Environ-
ment
error
Resetta-
ble
Reduce supply voltage.
Pay attention to techni-
cal data.
BM_E_G
Long
On
5x
rd
0x61
Supply voltage
too low
Low voltage
Environ-
ment
error
Resetta-
ble
Increase supply volt-
age or check system
topology. Pay attention
to technical data
and max. number of
modules/submodules.
Possibly excessively