![EUCHNER 163293 Operating Instructions Manual Download Page 49](http://html.mh-extra.com/html/euchner/163293/163293_operating-instructions-manual_2434724049.webp)
49
2540772-01-11/21 (translation of the original operating instructions)
Operating Instructions Bus Module
MBM-EC-..-MLI-… (EtherCAT)
EN
13.6. Teach-in errors and configuration errors
MBM
Err
or code
Err
or designation
Meaning
Err
or category
Err
or behavior
Tr
oubleshooting
Corr
esponding err
or/status
bit
LED displays
Bus module
L/A IN
EC ST
AT
L/A OUT
FSoE
DIA
MAINT
SF
POWER
0xAE
Configuration
error
Configuration
in the control
system does not
match the actual
configuration.
Modules might be
swapped or in the
wrong location.
Config-
uration
error
Latching
Restore the correct
configuration and
restart the system.
BM_E_G
3x
rd
0xEA
Topology error
Saved topology
does not match
the actual topolo-
gy. Modules might
be swapped or
in the wrong
location.
Topology
error
Latching
Restore the correct to-
pology and restart the
system. An intentional
change of the MLI
topology must be reset
via factory reset.
BM_E_G
Long
On
Long
On
0xEB
Topology error
Saved topology
does not match
the actual topolo-
gy. Modules might
have been added
or removed.
Topology
error
Latching
Restore the correct to-
pology and restart the
system. An intentional
change of the MLI
topology must be reset
via factory reset.
Interlocking/locking module
Err
or code
Err
or designation
Meaning
Err
or category
Err
or behavior
Tr
oubleshooting
Corr
esponding err
or/status
bit
LED displays
Interlocking/locking module
POWER
STAT
E
LOCK
DIA
SLOT 1
SLOT 2
0x1F
Actuator/handle
module could not
be taught-in
Actuator/handle
module not
detected often
enough during
teach-in opera-
tion or removed
during teach-in
operation
Teach-in error
Latching
Restart teach-in operation.
Make sure the handle module
is not removed during the
teach-in operation (door
closed, bolt tongue inserted).
LM_E_G
1x