![EUCHNER 163293 Operating Instructions Manual Download Page 8](http://html.mh-extra.com/html/euchner/163293/163293_operating-instructions-manual_2434724008.webp)
Operating Instructions Bus Module
MBM-EC-..-MLI-… (EtherCAT)
8
(translation of the original operating instructions) 2540772-01-11/21
The following applies to the MGB2-I… (or a correspondingly configured MGB2-L2):
Monitoring of the guard position
(interlocking device according to EN ISO 14119)
Ì
Safety function: When the guard is open, safety bit
LM_I_SK
(SK) = 0 (see chapter
12.2. Data blocks for interlocking/
locking module MGB2-I / MGB2-L
PFHD, Sys
PFHD, MBM
PFHD, MGB2-I
Interlocking
Device
MGB2-I...
Busmodule
MBM
EUCHNER
ModuleLink
-System (
MLI
)
Safetybit
LM_FI_SK_
(Interlock monitoring)
Failsafe
PLC
Ì
Safety characteristics:
category, Performance Level, PFH
D
(you will find the reliability values according to EN 13849-1 in the technical data).
3.2.
Safety functions on submodules with emergency stop
Emergency stop
(emergency stop device according to EN ISO 13850)
Ì
Safety function: evaluation of emergency stop
Ì
Safety characteristics: B
10D
value for the emergency stop in the submodule (MSM) and PL, PFH
D
, category and DC for
the evaluation electronics in the bus module (MBM)
PFHD, Sys
PFHD, MBM
PFHD, Module
MLI-Module
(e.g. Interlocking
Device MGB2-L...)
Busmodule
MBM
EUCHNER
ModuleLink
-System (
MLI
)
Safetybit
SM_FI_ES
(Emergency Stop)
B10D
Submodule
MSM with
Emergency
Stop
Failsafe
PLC