Add a suitable FSoE data module to the Safety Slot. It must be large enough that there is space for the individual safe data
bits for the modules/submodules in your system. On this topic, see also chapter
11.4. System layout and layout of the data
areas in the control system on page 24
Then add the suitable diagnostic module.
All further modules and submodules must then be added to the corresponding slots and subslots such that all devices are
displayed in the correct order. Only as many subslots as actually used in the corresponding module will be occupied.