Installation - Remote Connections
T-Max® 1A and 3A Remote Systems
In single sunbed installations, the T-Max® 1A
and 3A can offer the same control as the T-
Max® Manager, eliminating the need for a
Manager. If you’re using a 1A in this manner,
it must have a chip labelled “master” installed
on its circuit board. The remote control
bypass plug must not be used in this configu-
ration. The 3A may be used as a “master” with
no modification.
After you have set the T-Max® 1A’s, or 3A’s,
address to “0” (refer to your T-Max® user’s
guide) and the booth’s address to “1” (see
right), simply connect the RJ-22 modular
cables, described in the T-Max® user’s guide,
directly into either port located on the back of
the unit and either port on the back of the T-
Max® 1A or 3A. See
figure 2
.
Setting the address manually
Before connecting your booth to the T-Max®
Manager or T-Max® 1A or 3A, the address of
your booth must first be set. Set the “id” man-
ually as described below.
Setting the Address
1. Make sure the booth display is showing
“0”.
2. Press the red stop button and, without
releasing it, press the green timer button
and hold both for three seconds. The
display should indicate an address num-
ber from “1” to “255”.
3. If you are using a T-Max® 1A or 3A as a
“master” remote, the address of the
booth must be set to “1”. If you are
using a T-Max® Manager each sunbed
must be assigned a different address. To
adjust the address, press the green timer
button to count up until the desired
number (from 1 to 128) is achieved.
Addresses 252 to 255 are not normally
used.
4. Press the red stop button to return to the
normal display mode.
NOTE: A T-Max® 1A with a
“master” chip can be substi-
tuted for a 3A in
figure 2
.
figure 2
1-99
100-128
(blinking dot)
252-255
(blinking dot)