9 | 10
9
Attach the Service Doors and Remove the Holder
Attach the back-maintenance doors back onto the
enclosure and use the screw to secure it.
9-a
Remove the charging station off the holder and remove
the holder from the bracket. While doing this, hold the
charging station firmly as it is not supported anymore.
10
10-a
Attach Charger to the Wall Bracket
Attach the charging station to the wall bracket. First
attach it to the top hooks and gently push it towards the
wall. Tighten the screw until it is completely fastened
and charging station will be secured to the wall.
(10-b)
Installing Big Magnetic Cable Holder (Only for Model
with Longer Cable Attached)
Attach cable holder after you remove the charging
station from the station holder. To attach it, align the
holes on the cable holder hook with holes on the plate
attached to the enclosure.
11
Check Whether the Charging Station is Working
Properly and Setting of Maximal Charging Current
When the charging station has either overcurrent or RCD
protection installed, check whether the protection
element is in ON position.
11-a
Connect charging station to the power supply in the
electrical cabinet. Installation feeder should be turned
on.
11-b
The default value is 16 A and can be set to a maximum of
32 A. Information of the current value is obtained with
short press on the key. Number of short beeps
represents information of set maximal charging current
(number of beeps x 2 A).
Settings can be accessed with key press for more than
5 s. After that, a long beep is a notification that the
settings can be changed.
Summary of Contents for INCH LITE
Page 1: ...Ver 2020 08 EN Etrel INCH LITE QUICK START GUIDE EN...
Page 2: ......