BASE SPECIFICATIONS  

 

Input: 

230/400V~; 3W+N+PE; 50/60 Hz; 32A

max

 

 

Output: 

230/400V~; 3W+N+PE; 50/60 Hz; 32A

max

 

 

Maximum charging power: 

7.4 kW (1P), 22 kW (3P)

 

 

Device power consumption: 

from 1 W to 3 W 

Specification  of  frequency  bands  and  transmitting 
power (it is possible that not all modules are part of an 
actual device). 

LTE module

 

Frequency bands:  

LTE-FDD: B1 (2100 MHz), B3 

(1800 MHz), B5 (850 MHz), 

B7 (2600 MHz), B8 (900 

MHz), B20 (800 MHz) 

LTE-TDD: B38 (2600 MHz), 

B40 (2300 MHz), B41 (2500 

MHz) 

WCDMA: B1 (2100 MHz), B5 

(850 MHz), B8 (900 MHz) 

GSM/EDGE: B3 (1800 MHz), 

B8 (900 MHz) 

Transmitting power: 

33dBm±2dB for GSM 

24dBm+1/-3dB for WCDMA  

23dBm±2dB for LTE-FDD 

23dBm±2dB for LTE-TDD  

LTE Router  

Frequency bands: 

4G (LTE-FDD): B1 (2100 

MHz), B3 (1800 MHz), B5 

(850 MHz), B7 (2600 MHz), 

B8 (900 MHz), B20 (800 MHz) 

4G (LTE-TDD): B38 (2600 

MHz), B40 (2300 MHz), B41 

(2500 MHz) 

3G: B1 (2100 MHz), B5 (850 

MHz), B8 (900 MHz) 

2G: B3 (1800 MHz), B8 (900 

MHz) 

Transmitting power:  

21.9 dB

 

Wi-Fi module 

Frequency band:

  

2.4 - 2.4835 GHz

 

Transmitting power:

  

up to 15 dBm

 

RFID module

 

Frequency band:  

13.56 MHz (HF)

 

Transmitting power:  

up to 8 dBm 

Summary of Contents for INCH LITE

Page 1: ...Ver 2020 08 EN Etrel INCH LITE QUICK START GUIDE EN...

Page 2: ......

Page 3: ...harging station has been designed and tested in accordance with current and past versions of international standards The charging station is compliant with IEC 61851 Part 1 Part 21 2 Part 22 internati...

Page 4: ...trical codes legislation and ordinances Warning Before installing and wiring the charging station make sure that the power supply is disconnected remove fuses or deactivate the circuit breaker to prot...

Page 5: ...ll modules are part of an actual device LTE module Frequency bands LTE FDD B1 2100 MHz B3 1800 MHz B5 850 MHz B7 2600 MHz B8 900 MHz B20 800 MHz LTE TDD B38 2600 MHz B40 2300 MHz B41 2500 MHz WCDMA B1...

Page 6: ...d with an upstream overvoltage protection Overcurrent protection Should be installed upstream to protect power supply cable and the charging device Differential protection Should be installed separate...

Page 7: ...Optional depending on the purchased model INSTALLATION PROCEDURE The following descriptions are intended to be read together with appropriate image at the beginning of the document The bold number at...

Page 8: ...stallation should be around 40 cm Align holes of the mounting bracket with the drilled holes and tighten the screws using Phillips head screwdriver B2 Alternative Power Supply Cable Preparation When s...

Page 9: ...15 cm should be removed so that the wires lengths are sufficient to connect them to the elements inside the charging station You can now pull the power supply cable through the gland About 15 cm of p...

Page 10: ...tripping of RCD protection insert the additional wire with fork into the slot for neutral conductor like shown on the figure This applies only if RCD is installed in the charging station 8 Connecting...

Page 11: ...you remove the charging station from the station holder To attach it align the holes on the cable holder hook with holes on the plate attached to the enclosure 11 Check Whether the Charging Station i...

Page 12: ...tation can last up to 10 minutes Make sure that the status light is lit in solid green This means that the charging station is ready to charge an EV For more documentation and troubleshooting please v...

Reviews: