background image

Operating Instructions

STATICJET

RX22 Ion Blower Unit
with integrated High Voltage Generator 

BA-en-2083-1909

F000

62

y

Summary of Contents for STATICJET RX22

Page 1: ...Operating Instructions STATICJET RX22 Ion Blower Unit with integrated High Voltage Generator BA en 2083 1909 F00062y ...

Page 2: ...2 BA en 2083 1909_RX22 ...

Page 3: ...allation and assembly 11 3 1 Assembling the RX21 Ion Blower Unit STATICJET 11 3 2 Ground connection 12 3 3 Connecting the air hose 12 3 4 Connecting the supply voltage 12 3 5 Fault signal connection and external control 13 4 Operation 14 4 1 Startup 14 4 2 Function monitoring 14 5 Maintenance 15 6 Trouble shooting 17 7 Warranty 18 8 Technical specifications RX22 STATICJET 19 9 Dimensions 21 10 Spa...

Page 4: ...4 BA en 2083 1909_RX22 ...

Page 5: ... voltage compact design small dimensions and weight adaptable and easy to install three different nozzle designs To monitor the proper function of the unit the RX22 ion blower unit STATICJET is equipped with two LEDs which display normal operation or faults If a fault is detected the integrated circuit will switch off the high voltage and generate a fault signal Contact to the external control Ple...

Page 6: ...6 BA en 2083 1909_RX22 ...

Page 7: ...Grounding connection 4 Connection for compressed air supply 5 LED red fault signal 6 LED green high voltage OK 7 1 Nozzle attachment circular nozzle RX22 S 7 2 Nozzle attachment fishtail nozzle RX22 F 7 3 Nozzel attachment flexible hose RX22 P length 300 mm 8 4 x attachment bore holes M4 max screw in depth 5 mm Fig 1 RX22 Ion Blower Unit STATICJET with integrated high voltage generator Z 116821y ...

Page 8: ...t protection As the site of installation and or use of the units is outside the control of Eltex contact protection against inadvertent contact of the emission tip by personnel as specified by the employers liability insurance association have to be provided e g DGUV V3 in Germany Contact protection made of conductive material must professionally be grounded 2 3 Technical advance The manufacturer ...

Page 9: ...ng up the ion blower unit the user must make sure that the unit has been installed and assembled correctly Then first activate the air and then the supply voltage see chapter 4 1 Startup page 14 The maximum rated pressure is 0 2 MPa see chapter 3 3 Connecting the air hose page 12 The internal emission tip of the RX22 ion blower unit STATICJET must not be damaged For trouble free operation the tip ...

Page 10: ...ng during the operation of the system must not exceed the recommended value based on interna tional limits of 0 06 ml m 0 12 mg m Mechanical or electrical modifications of the RX22 ion blower units STAITCJET are not permitted Depending on the air pressure selected flow noise developing during the operation of the RX22 ion blower unit STATICJET may generate noise emission levels 85 dB A the appropr...

Page 11: ...unit must be freely accessible at all times and the display LEDs must be visible 2 x M4 threaded holes each are provided on either side of the enclosure to mount the RX22 ion blower unit STATICJET The maximum screw in depth is 5 mm assembly dimensions see Fig 2 Fig 2 Installation dimen sions RX22 Ion Blower Unit STATICJET Z 116818y 0 ...

Page 12: ... VDC line current designed for a min current of 120 mA per unit is required for operating the RX22 ion blower unit STATICJET Supply voltage is to be provided by the customer and connected via the plug supplied with the unit see Fig 4 Alternatively the power supply available as accessory may be used To ensure that no high voltage is generated when the material web is at rest we recommend releasing ...

Page 13: ...nal control NPN transistor output U max 27 V DC I max 20 mA The pin assignment is shown in Fig 4 In case of a short circuit of the remote contact and GND the high voltage supply is switched off Fig 4 Pin assignment Z 116822y MBSN 0 7 MBSN J 7 1PXFS 3 3FNPUF MBSN ...

Page 14: ...he unit If neither of the two LEDs lights up the supply voltage is switched off or both LEDs are defective If a fault has occurred e g high voltage sparking short circuit the high voltage will be cut off the green LED goes off and the red LED will come on a fault signal will be sent open collector the discharging effect is interrupted Note Faults will not be saved A disruption of the supply voltag...

Page 15: ... trouble free operation the tip must be straight and sharply pointed Defective emission tips must be replaced using the proper tools RX22 Ion Blower Unit STATICJET Dismantle the nozzle attachment to clean the emission tip Clean the emission tips at regular intervals using a soft nylon brush or a clean cloth For tough dirt e g grease ink adhesive etc clean the emission tip and the air outlet vent w...

Page 16: ...aution Risk of deflagration Allow the solvent to evaporate completely before restarting the RX22 ion blower unit STATICJET Recommended cleaning intervals after 100 200 hours Always make sure that the unit is probperly grounded ...

Page 17: ...e or repair work Maintenance work must be carried out by qualified electricians Failure Cause Measure No LED lights up No supply voltage Check supply voltage and connections Inform Eltex Service Red LED lights up Internal error To acknowledge the fault switch the supply voltage off and back on If the fault persists notify Eltex Ser vice ...

Page 18: ... the operating and assembly instructions spe cified by Eltex have been observed The warranty period begins on the date of delivery In the event of defects occurring during the warranty period the units or defective components will be repaired at Eltex Defective components will be replaced and installed free of charge If repairs are required at the customer s premises the costs for sending a techni...

Page 19: ...2 F 122 F max 80 r h non dewing LED on enclosure green high voltage active red malfunction NPN open collector U max 40 V DC I max 20 mA Da 8 mm outside tolerated hose max 0 2 MPa dry oil free filtered compressed air or nitrogen 0 40 C 32 104 F non dewing always avoid rapid changes in temperature socket contact with plug power supply as accessory available internal M4 thread on both sides of the en...

Page 20: ...ission dBA PSA personal protective equipment hearing protection Inlet air pressure for all nozzles typical values MPa 0 05 0 1 0 2 m h 5 7 5 12 MPa 0 05 0 1 0 2 RX22 S 80 85 92 PSA must be provided RX22 P 77 83 88 PSA must be provided RX22 F 64 68 72 ...

Page 21: ...BA en 2083 1909_RX22 21 9 Dimensions Fig 6 Dimensions RX22 ion blower unit STATICJET Z 116818y 0 ...

Page 22: ...e No Power supply for RX22 ion blower unit STATICJET 113677 Circular nozzle 116782 Fishtail nozzle 102954 Emission tip RX22 113261 Bit insert for tip changes 113262 Tube flexible L 300 mm 113065 Plug type connector G 1 4 DN10 113019 Combination plug strip 5 pin 116776 Operating Instructions specify language BA xx 2083 ...

Page 23: ......

Page 24: ... mbH Blauenstraße 67 69 79576 Weil am Rhein Germany Phone 49 0 7621 7905 422 eMail info eltex de Internet www eltex de Eltex offices and agencies The addresses of all Eltex agencies can be found on our website at www eltex de Z01007y ...