2.5 Work and operational safety
Warning!
Carefully observe the following notes and the complete
!
• Before carrying out repairs, cleaning or maintenance work and before
resetting after malfunctions, switch off the unit and disconnect the
mains supply voltage (see
chapter 5 "Maintenance”, page 15
).
• Any work involving the units must be carried out by qualified electri-
cians (see
chapter 5 "Maintenance”, page 15
).
• Before carrying out any work involving the units, the machine which has
the RX22 ion blower unit STATICJET fitted must not be in operation
(see
chapter 5 "Maintenance”, page 15
).
• A permanent ground contact must be made via the grounding connec-
tion (3, Fig. 1). The ground cable should have a minimum cross section
of 1.5 mm
²
(see
chapter 3.2 "Ground connection”, page 12
).
• A 24 VDC line current, designed for a min. current of 120 mA per unit, is
required for operating the RX22 ion blower unit STATICJET (see
ter 3.4 "Connecting the supply voltage”, page 12
).
• Before starting up the ion blower unit the user must make sure that the
unit has been installed and assembled correctly. Then first activate the
air and then the supply voltage (see
chapter 4.1 "Startup”, page 14
).
• The maximum rated pressure is 0.2 MPa (see
).
• The internal emission tip of the RX22 ion blower unit STATICJET must
not be damaged. For trouble-free operation, the tip must be straight and
sharply pointed (see
chapter 5 "Maintenance”, page 15
).
• Check the units at regular intervals and before startup for any damage.
Any damaged components must be repaired or replaced before conti-
n
uing to operate the unit, or the units must be disabled.
• Make sure that the units are clean at all times.
Dirt results in malfunctions and in premature wear of the units.
Do not immerse the RX22 ion blower unit STATICJET in solvent.
Allow the solvent to evaporate completely before restarting the RX22
ion blower unit STATICJET (see
chapter 5 "Maintenance”, page 15
).
• The operation of the RX22 ion blower units STATICJET can generate
ozone. The ozone concentration levels developing near the units
depend on many diffe-rent factors such as site of installation, air circu-
lation, etc., and can therefore not be specified in general terms.
If the maximum allowable concentration of ozone must be observed at