BA-en-2083-1909_RX22
15
5. Maintenance
Warning!
Electric shock hazard!
• Disconnect the supply voltage before carrying out any maintenance or
repair work.
• The machine in which the RX22 ion blower unit STATICJET is installed
must not be in operation.
• Maintenance work must be carried out by qualified electricians.
Caution!
The internal emission tip of the RX22 ion blower unit STATICJET must not
be damaged.
For trouble-free operation, the tip must be straight and sharply pointed.
Defective emission tips must be replaced using the proper tools.
RX22 Ion Blower Unit STATICJET
Dismantle the nozzle attachment to clean the emission tip.
• Clean the emission tips at regular intervals using a soft nylon brush or a
clean cloth.
• For tough dirt (e.g. grease, ink, adhesive etc.), clean the emission tip
and the air outlet vent with a suitable solvent (cleaning gasoline).
•
Caution!
Do not immerse the RX22 ion blower unit STATICJET in solvent.
Fig. 5:
Emission tip and
air outlet
Z-
1168
19
y_2
1 emission tip
2 air outlet holes of the nozzle
Summary of Contents for STATICJET RX22
Page 2: ...2 BA en 2083 1909_RX22 ...
Page 4: ...4 BA en 2083 1909_RX22 ...
Page 6: ...6 BA en 2083 1909_RX22 ...
Page 23: ......