TIME SWITCH 

 

FIG.1 

 

1. 

Time scale 

2. 

Schedules 

3. 

Text line 

4. 

Low-battery symbol 

5. 

Hour / Date 

6. 

C1 manual operation (blinking) /                   
C1 permanent manual (fixed) 

7. 

C1 relay status symbol 

8. 

Scroll down / C1 manual operation 

9. 

Go up   

10. 

Cancel option / Go back 

11. 

Accept option / Enter the menu /              
Switch on the device without power 

12. 

12 H / 24 H 

13. 

Days of the week 

 

 

OPERATING INSTRUCTIONS 

ETICLOCK-R1 is a digital time switch designed to control any electrical installation.  
It offers the possibility of performing different types of operations: ON and OFF at a set time, short-
term operations or pulses (1 to 59 seconds), and repetitive cycles (1 to 59 seconds or 1 minute to 23 
hours and 59 minutes). All of them can be applied to channel C1. 
Furthermore, it includes a series of additional functions such as: automatic DST changes, 4 holiday 
periods, adjustable screen brightness.  
Menus can be displayed in several languages and they show the schedule for the current day on screen. 
With  1  independent  and  voltage-free  circuit  switched,  which  allows  the  programming  of  up  to  40 
operations.  
 

INSTALLATION 

WARNING: Installation and mounting of electrical devices must be carried out by an authorised fitter. 

BEFORE PROCEEDING TO THE INSTALLATION, REMOVE POWER SUPPLY.   

The  device  is  internally  protected  against  interference  by  a  security  circuit.  However,  some 
particularly strong electromagnetic fields may alter its functioning. Interference can be avoided if the 
following installation rules are taken into account:  
- The device must not be installed near inductive loads (engines, transformers, contactors, etc.) 
- It is advisable to devise a separate line for supply (provided with a network filter if necessary). 
- Inductive loads must be provided with interference suppressors (varistor, RC filter). 
If the time switch is used in combination with other devices in an installation, it should be  made sure 
that the constituted unit does not generate extraneous disturbances.  

RESTORE SUPPLY ONCE THE DEVICE IS FULLY INSTALLED.  

 

MOUNTING 

Electronic  control  device  of  independent  mounting  in  fuse  box,  with  35  mm.  symmetrical  profile, 
according to EN 60715 standard (DIN Rail). 

 

CONNECTION  

Connect power supply according to the diagram in 

FIG. 2. 

Phase  and  Neutral  positions  must  be  respected,  checking  the  connections  made.  A  wrong 
connection may destroy the device.  

 

START-UP 
THE  DEVICE  MUST  BE  POWERED

  to  be  able  to  execute  the  installation  control.  When  this 

happens, the display will light up and the MAIN screen will appear.  
When the device is not powered the display remains off, storing all the date and time programming 
during  the  power-reserve  period  (10  years)  thanks  to  the  incorporated  lithium  battery.  If  installed 
without battery, the device has a security power-reserve of approx. 48 hours. 
With  the  device  unpowered,  when  pressing  the  MENU 

  key,  the  display  temporarily  lights  up  to 

allow programming. If after 5 seconds no key is pressed, the display will be turned off again.  
These devices have four keys for their setting and programming.  
The display shows the following information: 

 

Schedule  with  the  day’s  operations  (except  on  holidays).  A  schedule  for  each  channel  with  24 
divisions in which each segment represents 1 hour ON. 

  The display has a text line that will show the following information alternatively: 

 

Current date 

 PERMANENT operation 

 Active HOLIDAY period 

 

  Complete time.  

  Manual operation symbol

. It blinks when a manual switching is activated and if the switching 

is PERMANENT the symbol is fixed. 

  State of C1circuit: ON 

, OFF 

  

 

SETTINGS 

ETICLOCK-R1 is factory programmed with the current date and time, and configured as follows:  
 

  Time Mode:   

  

24 h 

  Standard to DST change: 

Automatic (last Sunday of March) 

  DST to Standard change:  

Automatic (last Sunday of October) 

  Holidays: 

 

NO (all 4 periods disabled) 

  Programs: 

 

None 

 

MANUAL OPERATION 

Activated or disabled, temporarily reversing the state of the circuit manually from the main screen, by 
pressing the ▼ C1.  
The  symbol 

 

will  appear  blinking  on  screen  over  the  handled  channel  until  we  press  ▼  C1 

again, returning to the previous state. 

 

PROGRAMMING  

Programming is based on menus and submenus through which we can move to program operations 

or adjust the device. The main menu can be accessed from the standby screen by pressing 

3

. With 

keys ▼ and ▲ we will move through the different menus and by pressing 

3

 we will access them. To 

go back to the previous menu we press 

C

.  

 
The details to be programmed always appear blinking on screen.  
 
The structure of the menus is the following: 
 
 
 
 

PROGRAMS 

3

 

ENTER 

3

 

PXX 

 

 

 

 

▲ 

 

3

 

 

 

 

 

DELETE 

 

EDIT 

▲ 

DELETE 

 

 

3

 

 

3

 

 

 

 

 

NO TO ALL 

 

TYPE 

 

 

 

 

▲ 

 

3

 

 

 

 

 

YES TO ALL 

 

CHANNEL 

 

 

ETI Elektroelement, d.o.o.,  

Obrezija 5, SI-1411 Izlake, Slovenia

 

Summary of Contents for 002472053

Page 1: ...FIG 2 Phase and Neutral positions must be respected checking the connections made A wrong connection may destroy the device START UP THE DEVICE MUST BE POWERED to be able to execute the installation c...

Page 2: ...gramming for the selected channel if we choose the YES OPTION o The contact position can be changed manually see MANUAL OPERATION o HOLIDAYS It has 4 PERIODS that can be programmed to perform the oper...

Page 3: ...a w a ciwe po o enie fazy i zera oraz sprawdzi wykonane pod czenie Nieprawid owe pod czenie mo e spowodowa uszkodzenie urz dzenia URUCHAMIANIE URZ DZENIE NALE Y W CZY aby umo liwi sprawdzenie instalac...

Page 4: ...nego kana u je eli zostanie wybrana opcja YES TAK o Po o enie styku mo e by zmieniane r cznie patrz PRACA W TRYBIE R CZNYM o HOLIDAYS WI TA Mo na zaprogramowa 4 PERIODS OKRESY aby wykonywane by y oper...

Page 5: ...d hendusi Valesti hendamine v ib h vitada seadme K IVITAMINE SEADE TULEB SISSE L LITADA selle ige paigaldamise kontrollimiseks Seda tehes s ttib ekraan ja kuvatakse p hiekraan Kui seadmel puudub toide...

Page 6: ...ja saab liikuda erinevate valikute vahel C1 YES jah C1 NO ei Soovitud valiku kinnitamine k ib klahviga 3 Seade ei arvesta valitud kanali tegevuse programmiga kui valida YES valik o Kontakti asendit s...

Page 7: ...ovjeru ostvarenog povezivanja Pogrje no povezivanje mo e uni titi ure aj POKRETANJE URE AJ SE MORA POKRENUTI da bi se izvr ila kontrola instalacije Kada se ovo uradi displej e se upaliti i GLAVNI ekra...

Page 8: ...ijeniti ru no vidjeti RU NO UPRAVLJANJE ODMORI Ima 4 PERIODA koji se mogu programirati da izvr e funkcije odabrane u programiranju PERIODA ODMORA Ukoliko nijedna funkcija nije programirana za period k...

Page 9: ...neitr les poz cijas Nepareizs savienojums var izn cin t ier ci UZS K ANA Lai var tu izpild t instal cijas vad bu IER CEI J B T PIESL GTAI PIE ELEKTROBARO ANAS Kad tas notiek displejs iedegsies un par...

Page 10: ...vai sekund s Lai pabeigtu mums nepiecie ams nor d t stundu min tes un ned as dienas kad is cikls p rtrauks darb bu PULSE TYPE PULS ANAS VEIDS Str vas des iesl g ana puls anas re m uz iestat to ilgumu...

Page 11: ...re mu kur v lamies redz t laiku M s p rbaud m atlasi ar pogu 3 o VERSIJA Izv lne kur tiek par d ta ier ces programmas versija Ja ir programm tas vienlaic gas darb bas mums nepiecie ams emt v r to ka d...

Page 12: ...b ti atsi velgta faz s ir neutral s pad tis patikrinant parengtas jungtis Netinkama jungtis gali sugadinti tais PALEIDIMAS TAIS TURI B TI TIEKIAMA ELEKTROS ENERGIJA kad b t galima atlikti rengimo kont...

Page 13: ...ti pakeista rankiniu b du r RANKINIS VALDYMAS o HOLIDAYS atostogos Galima u programuoti 4 laikotarpius PERIODS per kuriuos bus atliekamos operacijos pasirinktos programuojant atostog laikotarpius HOLI...

Page 14: ...na povezava lahko pokvari napravo ZAGON Za izvr itev nadzorne instalacije MORA BITI NAPRAVA PRIKLJU ENA NA EL TOK Ob tem se bo pri gal pokazovalnik in pojavil se bo GLAVNI zaslon Ko je naprava ugasnje...

Page 15: ...ZNIKI Obstajajo 4 OBDOBJA ki se lahko programirajo za izvr evanje na ina delovanja izbranega v programiranju PRAZNI NEGA OBDOBJA e ni programirano nobeno obdobke bodo kanali med omenjenim obdobjem ost...

Page 16: ...5 6 C1 C1 7 1 8 C1 9 10 11 12 12 24 13 ETICLOCK R1 1 59 1 59 1 23 59 C1 4 40 R 35 EN 60715 DIN 2 10 48 MENU 5 24 1 1 ETICLOCK R1 24 4 C1 C1 3 3 C 3 3 PXX 3 3 3 3 ETI Elektroelement d o o Obrezija 5 SI...

Page 17: ...eplaceable CR2032 lithium battery Battery replacement is made by removing the battery holder placed on the front of the device through a flat head screwdriver Observe the battery polarity as marked on...

Reviews: