INSTALLATION AND WIRING

Step 1 Prepare the switch box.

After the power is turned 

OFF

 at the circuit breaker box, remove the existing wall plate and mounting 

screws. Pull the old switch out from the wall box.

Step 2 Identify the type of circuit.

In a Single Pole Circuit (see Fig. 1), two single wires connect to two screws on the existing switch. A 

ground wire may also be present and connected to a ground terminal on the old switch. A neutral wire 

should also be present in the wall box.

NOTE: Only connect the RT-20 to a Single Pole Circuit. 

The RT-20 is not suitable for 3-way 

switching. If the existing wiring does not match the description for a Single Pole Circuit, you 

should consult with a qualified electrician.

CAUTION:

 For your safety: Connecting a proper ground to the time switch provides protection against electrical shock in the event of 

certain fault conditions. If a proper ground is not available, consult with a qualified electrician before continuing installation.

SPECIFICATIONS

Voltage  ............................. 120 - 277 VAC, 60 Hz (Single Phase)
Load (Single Pole Circuit)
 

Fan Motor ......................................................1/4HP @ 120V

Environment ......................................................... Indoor use only
Humidity ...............................................95% RH, non-condensing
Tools Needed
 

Insulated Screwdriver

 

Wire Strippers 

Incandescent or fluorescent lamp, E-Ballast, MLV, ELV, CFL, LED 

Drivers ..........................................................................0 – 800 VA
Time Delay .................................................. 5, 10, 15, 30 minutes
Operating Temperature .........................32° to 131°F (0° to 55°C)

DESCRIPTION AND OPERATION

The RT-20 is a time switch that turns 

OFF

 the connected light or fan when the selected time expires. An indicator light illuminates when 

the switch is 

OFF

. When selecting a time delay of 10 min or more, as time expires, the button LED’s will move through the next available 

time delay, always giving an indication of the amount of time left before the time delay expires. One minute before each time delay 

transition, the active button LED will flash, providing the user an indication of the transition.

Manual ON

Turn 

ON

 the connected light or fan by pressing the desired time button, or the 

ON/OFF

 button. If you press the 

ON/OFF

 button, it 

activates the timer that was last used.

Manual OFF

While a timer is active, you can press the 

ON/OFF

 button to turn 

OFF

 the connected light or fan without delay.

Changing the Selected Time

If you decide that you need more or less time than you originally selected, restart the time switch by pressing the button that matches the 

amount of time you think you’ll need.

WARNING:

 TURN THE POWER OFF AT THE 

CIRCUIT BREAKER BEFORE WIRING.

5

10

15

30

 

HOT (power from

circuit box)

NEUTRAL

LOAD

(power

to lamp)

Ground

Fig. 1: Typical Single Pole 

Switch Wiring

Summary of Contents for Wattstopper RT-20

Page 1: ...n SPECIFICATIONS Voltage 120 277 VAC 60 Hz Single Phase Load Single Pole Circuit Fan Motor 1 4HP 120V Environment Indoor use only Humidity 95 RH non condensing Tools Needed Insulated Screwdriver Wire Strippers Incandescent or fluorescent lamp E Ballast MLV ELV CFL LED Drivers 0 800 VA Time Delay 5 10 15 30 minutes Operating Temperature 32 to 131 F 0 to 55 C DESCRIPTION AND OPERATION The RT 20 is a...

Page 2: ...power from circuit box Red LOAD power to lamp or fan 5 10 15 30 Fig 3 Switch Orientation Wire Connections and Wall Box Assembly TROUBLESHOOTING To test the time switch The light above the ON OFF button should be ON when the switch is OFF Press the ON OFF button The connected light or fan comes ON The connected light or fan should turn OFF in the number of minutes indicated by the time selection in...

Page 3: ...pteur existant Un fil de terre peut également être présent et raccordé à la borne de terre de l ancien interrupteur Un fil neutre peut également être présent dans le boîtier mural REMARQUE Le RT 20 doit être raccordé à un circuit unipolaire uniquement Il ne convient pas pour un système tridirectionnel Si le branchement existant ne correspond pas à la description fournie pour un circuit unipolaire ...

Page 4: ... raccordé e doit s allumer Dans le cas contraire Vérifier l ampoule de la lampe et ou l interrupteur du moteur du ventilateur Coupez l alimentation du circuit et vérifiez le branchement des fils La lampe ou le ventilateur ne s allume pas le voyant de l interrupteur est éteint et aucun autre voyant n est allumé Cachez l interrupteur de la lumière extérieure pour vous assurer qu aucun voyant n est a...

Page 5: ...stente También podría haber un alambre de conexión a tierra conectado al borne de conexión a tierra del interruptor viejo También debería haber un alambre de conexión a neutro en la caja de conexiones de pared NOTA Sólo conecte el RT 20 a un circuito unipolar El RT 20 no es apropiado para conmutación de 3 vías Si el cableado existente no coincide con la descripción de un circuito unipolar usted de...

Page 6: ...ador no incluido Paso 7 Restaure el suministro eléctrico al circuito Coloque el disyuntores en la posición de encendido o coloque nuevamente el fusible IDENTIFICACION Y RESOLUCION DE PROBLEMAS Para probar el interruptor temporizado La luz encima del botón ENCENDIDO APAGADO debe estar en ENCENDIDO cuando el interruptor está apagado Oprima el botón de ENCENDIDO APAGADO La lámpara o ventilador conect...

Reviews: