MANUAL SGM800
86
Up
Down
Left
Right
Confirm
The following screen is visible:
In
gcL 2
you can set the
origin elevation
of the loadcell. This is the geographic
elevation of where the loadcell is manufactured. Press key 2 <2 sec. to set the origin
elevation.
The following screen is visible:
Use key 1 and key 2 to enter the origin elevation of the loadcell(s). Key 1 is used for
changing the number (1-9), key 2 is used for changing the position of the cursor. And
press key 3 >2 sec.to set the origin elevation. Choose value between –1000 and 30000
meter
.
Up
Down
Left
Right
Confirm
The following screen is visible:
In
gcL 3
you can set the
location latitude
of the loadcell(s). This is the
geographic latitude of where the loadcell is going to be used. Press key 2 <2 sec. to set
the location latitude.