Color temperature DMX values

The table below shows the color temperature value for each DMX value 
when using the 



 DMX control mode. Note that although DMX address 

0 = 3200 and DMX address 255 = 5600, the fixture supports a range of color 
temperatures from 2725 to 6450. 

Color 
Temp

DMX 

Value

Color 
Temp

DMX 

Value

Color 
Temp

DMX 

Value

3200

0–1

3425

49–50

4150

98–99

2725

2–3

3450

51–52

4175

100–101

2750

4–5

3475

53

4200

102

2775

6

3500

54–55

4225

103–104

2800

7–8

3525

56–57

4250

105–106

2825

9–10

3550

58

4275

107

2850

11

3575

59–60

4300

108–109

2875

12–13

3600

61–62

4325

110–111

2900

14–15

3625

63

4350

112

2925

16

3650

64–65

4375

113–114

2950

17–18

3675

66–67

4400

115–116

2975

19–20

3700

68–69

4425

117

3000

21

3725

70

4450

118–119

3025

22–23

3750

71–72

4475

120–121

3050

24–25

3775

73–74

4500

122

3075

26

3800

75

4525

123–124

3100

27–28

3825

76–77

4550

125–126

3125

29–30

3850

78–79

4575

127

3150

31

3875

80

4600

128–129

3175

32–33

3900

81–82

4625

130–131

3200

34–35

3925

83–84

4650

132–133

3225

36–37

3950

85

4675

134

3250

38

3975

86–87

4700

135–136

3275

39–40

4000

88–89

4725

137–138

3300

41–42

4025

90

4750

139

3325

43

4050

91–92

4775

140–141

3350

44–45

4075

93–94

4800

142–143

3375

46–47

4100

95

4825

144

3400

48

4125

96–97

4850

145–146

Summary of Contents for ColorSource Linear Pearl

Page 1: ...specifications subject to change ETC intends this document to be provided in its entirety US Patents 8 384 294 8 403 523 8 593 074 8 633 649 8 723 450 8 878 455 9 041 308 EU Patents 2638781 602011015...

Page 2: ...ls WARNING Disconnect the fixture from power and DMX and allow it to cool before performing any cleaning and maintenance Note The ColorSource Linear Pearl is for indoor use only Note Maximum recommend...

Page 3: ...rip curves when used with other equipment Requires power from a non dimmable source Inrush Linear 1 Linear 2 Linear 4 120V 35A 35 6A 67 5A first half cycle 240V 49A 85 6A 153A first half cycle Typical...

Page 4: ...or secondary lenses are included with the fixture Use these spacers to hold the accessories in position when multiple lenses are used in the Linear 2 and Linear 4 fixtures The spacers are positioned b...

Page 5: ...ntative and request part number W6538 for RJ45 to female XLR or part number W6539 for RJ45 to male XLR Connector locations Linear 1 Power connectors on one side of the fixture and data connectors on t...

Page 6: ...nnector on the rear of the fixture 2 Make any power thru cable connections prior to applying a power source 3 Make any DMX connections and if the fixture is the last in a DMX line terminate the fixtur...

Page 7: ...3 Tighten the trunnion locking knobs User interface The user interface allows you to set the start address of the fixture access the stand alone presets set the DMX control mode and set the Grouping m...

Page 8: ...he DMX address for the fixture You can also use RDM for DMX addressing See Using RDM on page 19 Changing the DMX control mode You can set the DMX control mode for the fixture to one of three available...

Page 9: ...fixture see Setting the DMX address on page 8 and the current DMX control mode see Changing the DMX control mode on page 8 For example if you set the DMX address on the fixture to 100 set the DMX mod...

Page 10: ...o strobe Use values of 1 254 to increase the strobe rate from 1 per second up to 33 per second DMX Channel Variable Color Temperature Direct 1 Channel 1 Cell 1 Intensity Cell 1 Intensity C1 Intensity...

Page 11: ...l Variable Color Temperature Direct 1 Channel 1 Cell 1 Intensity Cell 1 Intensity C1 Intensity 2 Color temperature Warm white C2 Intensity 3 Cell 2 Intensity Cool white C3 Intensity 4 Color temperatur...

Page 12: ...50 105 106 2825 9 10 3550 58 4275 107 2850 11 3575 59 60 4300 108 109 2875 12 13 3600 61 62 4325 110 111 2900 14 15 3625 63 4350 112 2925 16 3650 64 65 4375 113 114 2950 17 18 3675 66 67 4400 115 116...

Page 13: ...0 196 197 6150 233 234 5075 160 161 5625 198 6175 235 5100 162 163 5650 199 200 6200 236 237 5125 164 165 5675 201 202 6225 238 239 5150 166 5700 203 6250 240 5175 167 168 5725 204 205 6275 241 242 52...

Page 14: ...g DMX set the desired levels 2 Press the Mode button to access the Presets menu 3 Using the Up and Down buttons navigate to the preset number that you want to re record 4 Press and hold the Mode butto...

Page 15: ...to confirm your selection and return to the Presets menu The display will automatically return to the Presets menu after 10 seconds of inactivity and edits to the preset intensity will not be saved L...

Page 16: ...r software version to all connected ColorSource fixtures You can push newer software versions from a connected fixture only on ColorSource fixtures running software v1 3 0 or newer Use UpdaterAtor to...

Page 17: ...for secondary lenses are included with the fixture Use these spacers to hold the accessories in position when multiple lenses are used in the Linear 2 and Linear 4 fixtures 1 Loosen the thumbscrew on...

Page 18: ...ctory contact your local dealer to set up a repair Screen toggles between and to indicate that the fixture has gone into over temperature protection mode to avoid damaging the fixture Once the fixture...

Page 19: ...change the DMX address at the fixture however the fixture will return to sequential DMX addressing Linear 2 and Linear 4 fixtures in Group mode do not use sub devices RDM Values Manufacturer ID 0x657...

Page 20: ...en toggles between and to indicate that the fixture has gone into over temperature protection mode to avoid damaging the fixture Once the fixture has self cooled the error will automatically clear Scr...