background image

ETC Installation Guide

ColorSource Linear Pearl v1.7

ColorSource Linear Pearl v1.7

 Page 13 of 20

ETC

4875

147–148

5425

184–185

5975

221–222

4900

149

5450

186

6000

223

4925

150–151

5475

187–188

6025

224–225

4950

152–153

5500

189–190

6050

226–227

4975

154

5525

191

6075

228–229

5000

155–156

5550

192–193

6100

230

5025

157–158

5575

194–195

6125

231–232

5050

159

5600

196–197

6150

233–234

5075

160–161

5625

198

6175

235

5100

162–163

5650

199–200

6200

236–237

5125

164–165

5675

201–202

6225

238–239

5150

166

5700

203

6250

240

5175

167–168

5725

204–205

6275

241–242

5200

169–170

5750

206–207

6300

243–244

5225

171

5775

208

6325

245

5250

172–173

5800

209–210

6350

246–247

5275

174–175

5825

211–212

6375

248–249

5300

176

5850

213

6400

250

5325

177–178

5875

214–215

6425

251–252

5350

179–180

5900

216–217

6450

253

5375

181

5925

218

5600

254–255

5400

182–183

5950

219–220

Color 
Temp

DMX 

Value

Color 
Temp

DMX 

Value

Color 
Temp

DMX 

Value

Summary of Contents for ColorSource Linear Pearl

Page 1: ...specifications subject to change ETC intends this document to be provided in its entirety US Patents 8 384 294 8 403 523 8 593 074 8 633 649 8 723 450 8 878 455 9 041 308 EU Patents 2638781 602011015...

Page 2: ...ls WARNING Disconnect the fixture from power and DMX and allow it to cool before performing any cleaning and maintenance Note The ColorSource Linear Pearl is for indoor use only Note Maximum recommend...

Page 3: ...rip curves when used with other equipment Requires power from a non dimmable source Inrush Linear 1 Linear 2 Linear 4 120V 35A 35 6A 67 5A first half cycle 240V 49A 85 6A 153A first half cycle Typical...

Page 4: ...or secondary lenses are included with the fixture Use these spacers to hold the accessories in position when multiple lenses are used in the Linear 2 and Linear 4 fixtures The spacers are positioned b...

Page 5: ...ntative and request part number W6538 for RJ45 to female XLR or part number W6539 for RJ45 to male XLR Connector locations Linear 1 Power connectors on one side of the fixture and data connectors on t...

Page 6: ...nnector on the rear of the fixture 2 Make any power thru cable connections prior to applying a power source 3 Make any DMX connections and if the fixture is the last in a DMX line terminate the fixtur...

Page 7: ...3 Tighten the trunnion locking knobs User interface The user interface allows you to set the start address of the fixture access the stand alone presets set the DMX control mode and set the Grouping m...

Page 8: ...he DMX address for the fixture You can also use RDM for DMX addressing See Using RDM on page 19 Changing the DMX control mode You can set the DMX control mode for the fixture to one of three available...

Page 9: ...fixture see Setting the DMX address on page 8 and the current DMX control mode see Changing the DMX control mode on page 8 For example if you set the DMX address on the fixture to 100 set the DMX mod...

Page 10: ...o strobe Use values of 1 254 to increase the strobe rate from 1 per second up to 33 per second DMX Channel Variable Color Temperature Direct 1 Channel 1 Cell 1 Intensity Cell 1 Intensity C1 Intensity...

Page 11: ...l Variable Color Temperature Direct 1 Channel 1 Cell 1 Intensity Cell 1 Intensity C1 Intensity 2 Color temperature Warm white C2 Intensity 3 Cell 2 Intensity Cool white C3 Intensity 4 Color temperatur...

Page 12: ...50 105 106 2825 9 10 3550 58 4275 107 2850 11 3575 59 60 4300 108 109 2875 12 13 3600 61 62 4325 110 111 2900 14 15 3625 63 4350 112 2925 16 3650 64 65 4375 113 114 2950 17 18 3675 66 67 4400 115 116...

Page 13: ...0 196 197 6150 233 234 5075 160 161 5625 198 6175 235 5100 162 163 5650 199 200 6200 236 237 5125 164 165 5675 201 202 6225 238 239 5150 166 5700 203 6250 240 5175 167 168 5725 204 205 6275 241 242 52...

Page 14: ...g DMX set the desired levels 2 Press the Mode button to access the Presets menu 3 Using the Up and Down buttons navigate to the preset number that you want to re record 4 Press and hold the Mode butto...

Page 15: ...to confirm your selection and return to the Presets menu The display will automatically return to the Presets menu after 10 seconds of inactivity and edits to the preset intensity will not be saved L...

Page 16: ...r software version to all connected ColorSource fixtures You can push newer software versions from a connected fixture only on ColorSource fixtures running software v1 3 0 or newer Use UpdaterAtor to...

Page 17: ...for secondary lenses are included with the fixture Use these spacers to hold the accessories in position when multiple lenses are used in the Linear 2 and Linear 4 fixtures 1 Loosen the thumbscrew on...

Page 18: ...ctory contact your local dealer to set up a repair Screen toggles between and to indicate that the fixture has gone into over temperature protection mode to avoid damaging the fixture Once the fixture...

Page 19: ...change the DMX address at the fixture however the fixture will return to sequential DMX addressing Linear 2 and Linear 4 fixtures in Group mode do not use sub devices RDM Values Manufacturer ID 0x657...

Page 20: ...en toggles between and to indicate that the fixture has gone into over temperature protection mode to avoid damaging the fixture Once the fixture has self cooled the error will automatically clear Scr...

Reviews: