ETAS
Pin Assignment and Accessories
ES930.1
-
User Guide
111
14.2
Cable for Inputs and Outputs
The CBAV420.1 cable is used for the inputs, the CBAV421.1 cable for the out
-
puts and the CBAV422.1 cable for the Half-bridges (power stages) (see
Fig.
111 and the following table).
Fig.
14
-
10
Cable for Inputs and Outputs
For the connection of the inputs and outputs of the module, three CBAV420.1
cables, two CBAV421.1 cables and one CBAV422.1 cable are required.
The open connections of the cables CBAV420.1, CBAV421.1 and CBAV422.1
can be fitted individually by the user, so that it can be adapted to the specific
plug connector system of the measuring setup.
ES930.1 connection
Cable
TH1-4
Thermo channel Thermocouple
PS
Power stages
CBAV422.1
DO
Digital outputs
CBAV421.1
DI
Digital inputs
CBAV420.1
AO
Analog outputs CBAV421.1
AI 5-8
Analog inputs
CBAV420.1
AI 1-4
Analog inputs
CBAV420.1
CBAV421
CBAV420
CBAV420
CBAV420
CBAV421
CBAV422