ETAS
Technical Data
ES930.1
-
User Guide
92
13.9
Electrical Data
13.9.1
Power Supply
13.9.2
Host ("IN" Connection)
NOTE
Unless described otherwise, the electrical data of the ES930.1 were mea
-
sured directly at the contacts of the module.
Operating voltage
Operating voltage for the module at
"IN" connection:
7
V to 29
V DC
Separate operating voltage for the
Half-bridges at "PS" connection:
7
V to 32
V DC
Power consumption
1)
Typ. 4.5
W at 12
V
Power consumption
2)
Typ. 7.8
W at 12
V
Power consumption
Max. 15 W
Overvoltage category
(AC mains supply)
II
1)
: without sensor supply
2)
: with sensor supply, 30
mA load at 15
V
Connection
100Base-T Ethernet; 100
Mbit/s,
full duplex
Protocol
XCP on UDP/IP
IP address
Dynamic via INCA or
ES93x
Configuration
Tool
(default setting 192.168.40.44)
NOTE
For the successful initialization of the network card of your PC, observe chap
-
90.