ETAS
Technical Data
ES921.1
-
User Guide
33
Low-Speed CAN
High-Speed CAN
High-Speed CAN “Wake-Up” Signal Conditions
At least two signal edges of the same polarity must be within a time of 100
ms.
Miscellaneous
Transceiver (physical layer)
TJA1054
Transfer speed
Max. 125
kBaud
Transceiver (physical layer)
TJA1040
Transfer speed
Max. 1
MBaud with a bus length of 20
m
Differential internal resistor Ri
10
kOhm
Differential input voltage (min.)
V_diff,min
=
0.2
V
Signal edge increase rate
t/dV
<
150
ns/V
Differential input resistor
R i,diff
=
10 kOhm
Functions
Wake-Up, Sleep
LED
Status display of CAN bus