ETAS
Technical Data
ES921.1
-
User Guide
32
7.8.3
ES921.1 Firmware
7.8.4
Environmental Conditions
7.8.5
Mechanical Data
7.9
Electrical Data
7.9.1
Power Supply
7.9.2
CAN Interfaces
NOTE
As delivered, the ES910 module contains
no
firmware to support the modules
mountable in the extension slot.
The required firmware has to be loaded additionally (see chapter 5.4
on
20).
Temperature range (operation)
Complies with ES910.3-A:
-40
°C to +50
°C / -40
°F to +122
°F
Temperature range (storage)
-40
°C to +85
°C
-40
°F to +185
°F
NOTE
The module is suitable for use in interiors, in the passenger cell or in the trunk
of vehicles. The module is
not
suitable for installation in the engine compart
-
ment and similar environments.
Dimensions (H x W x D)
20 mm x 35 mm x 83 mm
0.79 in x 1.38 in x 3.27 in
Weight
Approx. 50
g / 0.11 lb
Operating voltage
Power supply via extension slot of the
ES910
Input voltage
3.3
V; 5
V
Power consumption (operation)
0.8
W (typ.);
1.0
W (max.)
Current consumption (standby)
< 0.62
mA
CAN1 and CAN2
2 independent interfaces,
galvanically isolated from each other,
every interface can be configured indi
-
vidually (High-Speed / Low-Speed CAN)
Protocols
CAN V2.0a (Standard Identifier),
CAN V2.0b (Extended Identifier)
Controller
IP-Core (FPGA)