ETAS
Getting Started
ES921.1
-
User Guide
27
6.4.2
Configuring the “Wake Up” Function of the ES921.1 Module
To launch the ES910 web interface:
1. Connect the ES910 to the PC.
2. Start the HSP program on the PC.
3. Click
Hardware Search
.
4. Highlight the ES910 to be configured in the “Hardware” win
-
dow.
5. Right-click
System Configuration
.
The default web browser launches the web interface for con
-
figuring the ES910 with the current IP address of the module in
the address field.
The home page of the ES910 web interface is displayed.
To configure the “Wake Up” function:
1. Click
Config
.
2. Click
Wake Up
.
The page for configuring the “Wake Up” function is displayed.
3. Configure the interfaces of the ES921.1 for the “Wake Up” func
-
tion.
6.5
Troubleshooting
Please observe the LEDs which provide information on the functions of the
ports and the ES921.1 (see the section “LED” on page
16) to be able to judge the
operational state of the ES921.1 as well as troubleshooting measures.
The following table lists one possible problem with a remedy.
If you have any further questions, please contact our Customer Support (see
chapter 10 on
39).
Problem
Diagnostic Questions
Possible Solutions
The ES921.1 is not found
in HSP with “Search for
Hardware”.
Is the hardware con
-
nected to the PC with the
CBE100 cable?
Check that the connec
-
tion is undamaged.