Buffer storage tank
Hydraulic integration
29
With hot water tank
1
Boiler flow, heating circuits, hot water tank, oil/gas
boiler
2
Temperature sensor [Sensor 1 (upper)]
3
Oil/gas boiler return
4
Temperature sensor [Sensor 2]
5
Hot water tank return
6
Boiler, heating circuits return
7
Temperature sensor [Sensor 3]
The temperature sensor [Sensor 3] must always
be positioned just above the lowest return
connection.
This is also important for buffers from third parties so
that they are not positioned beneath the lowest return
connection.
With fresh water module
1
Fresh water module flow
2
Boiler, heating circuits, oil/gas boiler flow
3
Temperature sensor [Sensor 1 (upper)]
4
Oil/gas boiler return
5
Temperature sensor [Sensor 2]
6
High-temperature circuits return
7
Temperature sensor [Sensor 3]
8
Fresh water module return
9
Boiler, low-temperature circuit return