Fault
Cause/solution
The controlled bright-
ness does not match
the specified light
target value
• The interior design (e.g. darker carpet) can
result in the detector or light sensors receiv-
ing too much or too little reflected light.
•
Solution
:
A
. If you use lights with light sensors, cal-
ibrate the light sensors. The light sensors
can be calibrated using the remote control
(see Chapter “Calibration” page
using the app (see Chapter “Configuring via
light sensors” page
B
. If light measurement is performed by the
DALI detector:
1. Use a lux meter to measure the bright-
ness in the area around the light.
2. Compare the brightness value with the
specified light target value.
3. Adjust the sensitivity of the detector
using the remote control function "Detector
Light Factor" (Chapter 8.15). If the con-
trolled brightness is too low, the light factor
must be reduced.
17 Technical data
Mains voltage
230 V ~/50 Hz
Rated output
10 W–130 W (130 W: maximum value when
connecting four lights)
Stand-by consumption
< 4 W
Permissible ambient
temperature
0 °C to +40 °C
Approx. dimensions
474 * 255 * 75 mm
Installation type
Ceiling mounting
Terminal
2.5 mm
2
/1.5 mm
2
Interfaces
ESYLUX Light Control, DALI:
Only models CU- to KNX: ESYLUX Light Control,
DALI, KNX)
Operating interfaces
All models: Infrared, connection for button
Models CU-ELC Box DALI BT:
Infrared, connection for push button, Bluetooth
Interface for connecting
presence detectors
DALI
Housing material
Steel, galvanised