GB
18 / 44
MA01708100
Installation and connection
DANGER!
Risk of fatal injury from electric shock!
¾
Switch of the mains voltage before installing / removing the detector.
¾
Check that the mains voltage is de-energised.
Installation steps:
¾
Disconnect the sensor unit from the mounting bracket. These are
connected via a plug-in connection.
¾
Feed the cable into the detector and install the mounting base in
the required position.
The distances between the screw holes
are compatible with
those of the RC series of outdoor motion detectors from ESYLUX.
The distances between the screw holes
are suitable for
conventional recessed boxes (60 mm).