8. List of SUSI-CVs

CV Description

Value

900 Manufacturer ID 

151

901 version number 

0

902 function key to turn the smoke generator 

1

903 Stop state - temerature 

175

904 State Drive - Temperature 

190

905 state Acceleration - Temperature 

210

906 state Coast - Temperature 

180

907 state stop - Fan speed 

30

908 state drive - Fan speed 

80

909 state Acceleration - Fan speed 

120

910 state Coast - Fan speed 

40

911 threshold transition Drive <=> Acceleration 

3

912 threshold transition Drive <=> Coast 

3

913 Minimum duration of a steam burst 

20

914 Maximum duration of a steam burst 

80

915 duration of the bursts of steam relative to trigger pulses  50

CV-List

Copyright 1998 - 2013 by ESU GmbH & Co KG. Subject to errors, omissions regarding technical advancement, availability and all other Rights reserved. Electrical and me-

chanical measurements and pictures without guarantee. Any liability for consequential damages due to improper Use, non-compliance with these instructions, unauthorized 

modifications. Ä is. Excluded. Not suitable for children under 14 years. improper Use may result in injury.

Märklin and mfx® are registered trademarks of Gebr. Märklin® and Cie. GmbH, Göppingen. RailCom® is a registered trademark of Lenz® Elektronik GmbH, Giessen. 

RailComPlus® is a registered trademark of Lenz Elektronik GmbH, Giessen. LocoNet ™ is a registered trademark of. Digitrax, Panama City, USA. All other trademarks are the 

property of their respective owners. ESU GmbH & Co. KG operates a policy of continuous development. Therefore, ESU reserves the right, without prior Notice to any of the 

products described in the document changes and improvements. Any copy or reproduction of this document in any form without prior written consent from ESU

Summary of Contents for 54678

Page 1: ...Installation and Operating instructions 1 Edition March 2015 P N 01515 16039 54678 Smoke generator small 0 Gauge 54679 Smoke generator large G Gauge ESU Smoke Generator...

Page 2: ...roduct Product name Smoke Generator Track 0 Smoke Generator Track 1 Type 54678 54679 EN 55014 1 2006 A1 2009 Electromagnetic compatibility Requirements for household appliances electric tools and simi...

Page 3: ...cur 4 General characteristics The two ESU smoke generators provide realistic smoke and steam cloud to your models An integrated control operates both the fan motor and the heating of the smoke generat...

Page 4: ...meter for cylinder steam elbow to deflect the smoke flow to the cylinders Suitable screws headers Scope of delivery If you want to use the smoke generator as a steam cylinder all you have to do is rem...

Page 5: ...cannot damage the smoke generator Always fill the system on a flat surface never on a slanted surface Turn overfilled locomotives upside down to allow excess to drain in order to prevent leakage of s...

Page 6: ...6 The SUSI connector of the module as a usual coder is connected directly to the disassembly As for the connected coder use assem bly shown with the parts provided For this initial work the CVs have t...

Page 7: ...s however imperative to have a LokProgrammer 53451 53452 because you need to change settings in the sound sequencing You must first change the desired sound project load it into the LokProgrammer and...

Page 8: ...done in register Function assignment In the mapping line of the desired function key the logical function ESU smoke generator could be selected In our example this is the F4 key 6 1 2 Sound synchronis...

Page 9: ...ties change interactively depending on what was in the tile marked on the top right Transitions are triggered by a white rectangle shown Click with your mouse the Stop as in the shown figure To adjust...

Page 10: ...eam boost Not set The actual speed steps in all ESU projects with Dx referred to Some sound projects include D1 to D4 other go to D8 These are the normal bursts of steam Here you should experiment wit...

Page 11: ...he power cycle on Adjusting the fan speed Here the fan speed will be changed rela tive to the values set in the sound sequencing Adaptation of the heating temperature Here the heating tem perature wil...

Page 12: ...on the decoder The flue settings can be written together with the sound data 6 2 For other decoder SUSI When operating with other decoders from the SUSI interface usually only the current speed and t...

Page 13: ...s where they are located These two connections to the output must be connected to the LokProgrammer 7 Support and help If you do not know how to proceed first contact your dealer whe re you purchased...

Page 14: ...ty and all other Rights reserved Electrical and me chanical measurements and pictures without guarantee Any liability for consequential damages due to improper Use non compliance with these instructio...

Page 15: ...the enclosed failure report card as detailed and precise as possible and return it with your faulty product Please use the appropriate postage when shipping to ESU Extend of warranty exclusions This w...

Page 16: ...l system ESU ECoS M rklin 6012 ROCO Digital LGB Digital LGB MZS Intellibox Lenz Digital Others 3 Error description Headlight output front No Sound Cable Headlight output rear Wrong Sound Changedirecti...

Reviews: