The relationship is as follows:

For  each  state,  the  desired  heating  temperature  and  fan  speed 

must be set. Section 7 provides information on the CV numbers.

Furthermore, you can still set when the transition to drive to ac-

celeration drive occurs after coast is cancelled. The corresponding 

thresholds  define  the  acceleration  or  deceleration  values,  from 

which the smoke generator is to change the mode. Finally, the mi-

nimum in the SUSI mode, the maximum steam burst length, and 

the duration of the bursts of steam can be adjusted in proportion 

to their distance.

6.3. Firmware update with LokProgrammer

Of course, the ESU smoke generator using the ESU LokProgram-

mer can be supplied with a new firmware. For this purpose, the 

smoke generator must be removed, however, and then connec-

ted to the LokProgrammer.  Two separate solder connections are 

available  for  this.  These  are  marked  «PROG».  Figure  17  shows 

where they are located. These two connections to the output must 

be connected to the LokProgrammer.

7. Support and help

If you do not know how to proceed, first contact your dealer whe-

re you purchased your ESU product. He is your competent partner 

for all questions about model trains.

In  difficult  cases,  you  can  contact  us  directly.  Look  first  on  our 

website under «Support / FAQ» to see whether the question has 

already been answered. If this is not the case, we ask you to make 

these available to us either in our support forum or to contact us 

by e-mail. We also provide a telephone hotline, which should only 

be used in the case of really special requests.

Germany

By phone: 

+49 (0) 731 - 1 84 78 - 106

 

 

Tuesday & Wednesday

 

 

from 10.00 to 12.00 o‘ clock

By Fax:                        +49 (0) 731 - 1 84 78 - 299
By E-Mail:  

www.esu.eu/kontakt

By mail:  

ESU GmbH & Co. KG

 

 

Edisonallee 29

                                   D-89231 Neu-Ulm

 

 

www.esu.eu

USA

ESU LLC
By phone: 

+1 570-980-1982

By Fax:   

+1 866-591-6440

By E-Mail:  

[email protected]

By mail:  

ESU LLC

 

 

23 Howard Street

                                   Montoursville PA 17754

 

 

www.loksound.com

Programming

54678 & 54679 solder connections for LokProgrammer

Figure 17: 

Summary of Contents for 54678

Page 1: ...Installation and Operating instructions 1 Edition March 2015 P N 01515 16039 54678 Smoke generator small 0 Gauge 54679 Smoke generator large G Gauge ESU Smoke Generator...

Page 2: ...roduct Product name Smoke Generator Track 0 Smoke Generator Track 1 Type 54678 54679 EN 55014 1 2006 A1 2009 Electromagnetic compatibility Requirements for household appliances electric tools and simi...

Page 3: ...cur 4 General characteristics The two ESU smoke generators provide realistic smoke and steam cloud to your models An integrated control operates both the fan motor and the heating of the smoke generat...

Page 4: ...meter for cylinder steam elbow to deflect the smoke flow to the cylinders Suitable screws headers Scope of delivery If you want to use the smoke generator as a steam cylinder all you have to do is rem...

Page 5: ...cannot damage the smoke generator Always fill the system on a flat surface never on a slanted surface Turn overfilled locomotives upside down to allow excess to drain in order to prevent leakage of s...

Page 6: ...6 The SUSI connector of the module as a usual coder is connected directly to the disassembly As for the connected coder use assem bly shown with the parts provided For this initial work the CVs have t...

Page 7: ...s however imperative to have a LokProgrammer 53451 53452 because you need to change settings in the sound sequencing You must first change the desired sound project load it into the LokProgrammer and...

Page 8: ...done in register Function assignment In the mapping line of the desired function key the logical function ESU smoke generator could be selected In our example this is the F4 key 6 1 2 Sound synchronis...

Page 9: ...ties change interactively depending on what was in the tile marked on the top right Transitions are triggered by a white rectangle shown Click with your mouse the Stop as in the shown figure To adjust...

Page 10: ...eam boost Not set The actual speed steps in all ESU projects with Dx referred to Some sound projects include D1 to D4 other go to D8 These are the normal bursts of steam Here you should experiment wit...

Page 11: ...he power cycle on Adjusting the fan speed Here the fan speed will be changed rela tive to the values set in the sound sequencing Adaptation of the heating temperature Here the heating tem perature wil...

Page 12: ...on the decoder The flue settings can be written together with the sound data 6 2 For other decoder SUSI When operating with other decoders from the SUSI interface usually only the current speed and t...

Page 13: ...s where they are located These two connections to the output must be connected to the LokProgrammer 7 Support and help If you do not know how to proceed first contact your dealer whe re you purchased...

Page 14: ...ty and all other Rights reserved Electrical and me chanical measurements and pictures without guarantee Any liability for consequential damages due to improper Use non compliance with these instructio...

Page 15: ...the enclosed failure report card as detailed and precise as possible and return it with your faulty product Please use the appropriate postage when shipping to ESU Extend of warranty exclusions This w...

Page 16: ...l system ESU ECoS M rklin 6012 ROCO Digital LGB Digital LGB MZS Intellibox Lenz Digital Others 3 Error description Headlight output front No Sound Cable Headlight output rear Wrong Sound Changedirecti...

Reviews: