ESTeem 195C User Manual Download Page 8

CHAPTER

 

1

 

INTRODUCTION

 

 

Revised: 15 Feb 2017 

1-2 

ESTeem Models 195MHC 

without

 

any

 

handshaking.

  

The

 

second

 

RS

232

 

port

 

(Port

 

3)

 

has

 

full

 

hardware

 

handshaking

 

through

 

the

 

request

 

to

 

send

 

(RTS)

 

and

 

clear

 

to

 

send

 

(CTS)

 

lines.

  

Both

 

RS

232

 

ports

 

are

 

software

 

configurable

 

from

 

2,400

 

to

 

115,000

 

bps.

 

 

RS

422

 

 

The

 

ESTeem

 

195M/H/C

 

has

 

a

 

single

 

RS

422

 

data

 

port

 

(Port

 

2).

  

The

 

RS

422

 

data

 

port

 

is

 

shared

 

on

 

the

 

front

 

panel

 

with

 

the

 

10/100

 

Mbps

 

Ethernet

 

interface.

  

The

 

RS

422

 

interface

 

is

 

typically

 

used

 

for

 

long

 

distances

 

to

 

4,000

 

feet

 

at

 

bauds

 

rate

 

software

 

configurable

 

from

 

2,400

 

to

 

115,000

 

bps.

 

 

RS

485

 

 

The

 

ESTeems

 

have

 

a

 

single,

 

two

wire

 

RS

485

 

data

 

port

 

(Port

 

1).

  

The

 

RS

485

 

data

 

port

 

is

 

shared

 

on

 

the

 

front

 

panel

 

with

 

the

 

4/20mA

 

sensors.

  

The

 

RS

485

 

interface

 

is

 

typically

 

used

 

for

 

long

 

distances

 

to

 

4,000

 

feet

 

at

 

baud

 

rates

 

software

 

configurable

 

from

 

2,400

 

to

 

115,000

 

bps.

 

 

 

Ethernet

 

Applications

 

  

The

 

ESTeem

 

195M/H/C

 

has

 

a

 

10/100

 

Mbps

 

Ethernet

 

interface

 

(Port

 

2)

 

that

 

is

 

used

 

as

 

both

 

a

 

data

 

port

 

and

 

the

 

primary

 

programming

 

port.

  

When

 

the

 

Ethernet

 

port

 

is

 

used

 

as

 

a

 

data

 

port

 

there

 

are

 

two

 

modes

 

of

 

operation.

  

The

 

primary

 

use

 

will

 

be

 

as

 

a

 

slow

 

speed

 

(12.5

 

Kbps)

 

Ethernet

 

bridge

 

to

 

remote

 

locations

 

to

 

gather

 

data

 

from

 

remote

 

Ethernet

 

devices.

  

The

 

secondary

 

mode

 

of

 

operation

 

is

 

to

 

configure

 

the

 

Ethernet

 

port

 

as

 

a

 

TCP

 

or

 

UDP

 

Socket

 

and

 

write

 

custom

 

software

 

applications

 

to

 

access

 

the

 

data

 

port.

  

Each

 

of

 

these

 

modes

 

of

 

operation

 

are

 

described

 

in

 

detail

 

in

 

Chapter

 

5.

  

 

 

Sensor

 

Applications

  

 

The

 

ESTeem

 

195C

 

and

 

195M

 

have

 

four

 

(4)

 

4/20mA

 

sensor

 

inputs.

  

The

 

sensor

 

inputs

 

can

 

be

 

read

 

out

 

of

 

the

 

195M/H/C

 

though

 

their

 

ModbusTCP

 

address,

 

a

 

software

 

command

 

or

 

the

 

Model

 

195M/H/C

 

configuration

 

utility.

   

For

 

complete

 

details

 

on

 

the

 

configuration

 

and

 

operation

 

of

 

the

 

sensor

 

input,

 

please

 

refer

 

to

 

Appendix

 

B

 

 

Interface

 

Ports.

  

 

 

Legacy

 ‐ 

Model

 

192

 

Applications

 

 

The

 

ESTeem

 

195C

 

can

 

be

 

integrated

 

with

 

our

 

legacy

 

ESTeem

 

Model

 

192C

 

or

 

Model

 

192CHP,

 

while

 

the

 

195M

 

can

 

be

 

integrated

 

with

 

Models

 

192M

 

or

 

192MHP

 

networks.

  

The

 

procedure

 

for

 

integrating

 

the

 

new

 

195C

 

or

 

195M

 

in

 

an

 

existing

 

Model

 

192

 

network

 

can

 

be

 

found

 

in

 

Appendix

 

C

 

of

 

this

 

User’s

 

Manual.

  

 

To

 

begin

 

setup

 

of

 

your

 

wireless

 

Ethernet

 

network,

 

continue

 

to

 

Chapter

 

2

 ‐ 

Staring

 

Out

 

of

 

this

 

User’s

 

Manual.

 

Summary of Contents for 195C

Page 1: ...ESTeem User s Manual Models 195M 195H 195C Manual Revision 2 3 October 2017 ESTeem Industrial Wireless Solutions...

Page 2: ...Technology Inc All rights reserved Printed in the United States of America No part of this publication may be reproduced stored in a retrieval system or transmitted in any form or by any means electr...

Page 3: ...zed RMA Return Materials Authorization Number before shipment of product or parts to ESTeem for any reason b If the whole unit is shipped it must be in its original carton and shipping components or a...

Page 4: ...Description and Examples 3 1 Transparent Point to Point 3 1 Transparent Multipoint 3 3 PLC Emulations 3 4 Programming Examples 3 5 Using Model 195C M H Configuration Utility 3 5 Example 1 Transparent...

Page 5: ...Console 6 7 Diagnostics 6 7 Spectrum Analyzer 6 8 MURS Frequency Applications 6 8 CHAPTER 7 Antenna Setup Coax Cables 7 1 Weatherproofing 7 2 Grounding 7 2 SWR Testing 7 2 Example Antenna Configuratio...

Page 6: ...TABLE OF CONTENTS Revised 15 Feb 2017 Page 3 ESTeem Models 195CMH APPENDIX F 195C Specifications APPENDIX G 195M Specifications APPENDIX H 195H Specifications...

Page 7: ...view The ESTeem Model 195M H C are wireless modem transceivers that can be used to build many types of Wireless Local Area Networks WLAN The ESTeem 195M H C series have multiple serial RS 232 RS 422 a...

Page 8: ...t When the Ethernet port is used as a data port there are two modes of operation The primary use will be as a slow speed 12 5 Kbps Ethernet bridge to remote locations to gather data from remote Ethern...

Page 9: ...re and test communication After the ESTeem Model 195M H C s programming install the hardware in each remote location Chapter 7 of this User s Manual describes the antenna specifications mounting optio...

Page 10: ...C 1 Connect the antenna cable to the TNC connection on the ESTeem Model 195M H C Figure 1 2 Connect the power supply and Ethernet cable to the ESTeem Complete the Software Configuration below and proc...

Page 11: ...tp www winpcap org The version required will be based upon your operating system 2 Once both the above programs have been installed save the ESTeem exe file to any location on your computer such as th...

Page 12: ...nel Layout The single Status LED has multiple colors representing the following Off No Activity Blue Model 195M H C has established a wireless link Red Model 195M H C is transmitting an RF packet Gree...

Page 13: ...l or Ethernet data between two or more wireless modems as if they were connected by a cable Point to point operation is when two serial or Ethernet devices are transferring information between either...

Page 14: ...CHAPTER 3 EXAMPLE APPLICATIONS Revised 10 Oct 2017 3 2 ESTeem Models 195MHC Figure 2 Point to Point with Repeater...

Page 15: ...interfaces RS 232 RS 422 RS 485 or Ethernet on either end of the wireless link These wireless links are independent of each other and configurable Example Applications Point to multipoint serial netwo...

Page 16: ...ocols Supported Rockwell Automation Allen Bradley DF1 Full Duplex Rockwell Automation Allen Bradley DF1 Half Duplex Rockwell Automation Allen Bradley DF1 Radio Modem Modbus RTU ASCII ModbusTCP Opto 22...

Page 17: ...nd open the 195 Narrowband Configuration Utility Figure 5 Press the Discover EST Modems button to continue 2 The ESTeem 195M H C will be displayed Figure 5 If the ESTeem 195M H C is not on the same IP...

Page 18: ...456 500 MHz 3 Set the destination address to the last octet in Remote Site address 181 4 Set the data interface to the RS 232 DATA port Port 3 5 Set the operating mode to Transparent Once all the abo...

Page 19: ...00 MHz 3 Set the destination to the Remote Site address including the repeater 200 181 The 195M H C RF link will follow the exact path as written in this field For example the data will first be sent...

Page 20: ...ut verify and continue 2 Set the operating frequency to 456 500 MHz 3 Click the Global check box Figure 12 and the Destination address will be set to 255 4 Set the data interface to the RS 485 DATA po...

Page 21: ...e 2 Set the operating frequency to 456 500 MHz 3 Set the destination to any remote site address address 181 used for example 4 Set the data interface to the RS 232 DATA port Port 3 5 Set the operating...

Page 22: ...182 and an end address of 183 Append entry 2 will use repeater route 2 and addresses 184 through 185 will use this route Once all repeater entries have been completed press the Write Tables button Fi...

Page 23: ...in the repeating ESTeems or the remote ESTeems Figure 1 shows a complex 16 node site with four 4 repeater routes This example will illustrate the terms used in the utility and how they correspond to...

Page 24: ...address 3 Type 3 in the first repeater block The second repeater from the master is address 20 Type 20 in the second repeater block Addresses 40 through 42 use this route Type 40 in the first address...

Page 25: ...Model 195 Narrowband Configuration Utility and press the Read Tables button Figure 7 displays the saved Routes and Appends for the wireless network shown in Figure 1 Clearing Route and Append Tables...

Page 26: ...hernet port is used for both programming the Model 195M H C and data transfer The Ethernet port on the 195M H C is used as the primary interface when programming with the 195 Narrowband Configuration...

Page 27: ...e mode 1 Set the Data Interface in the 195 Series Narrow Band Configuration Tool to Ethernet 10 100 and Static Ethernet Bridge Figure 2 2 Verify the IP address for the 195M H C and note the Address sh...

Page 28: ...or configuring the Route Append tables The Wizard View will guide you through the configuration of the Route Append table by asking simple questions on remote IP addresses The Wizard View is a more si...

Page 29: ...ill be displayed This simplified entry method asks for the remote ESTeem address Destination and the remote IP address range If repeaters are used check the box next to the repeater and enter the IP a...

Page 30: ...ess of the repeater ESTeem 172 16 10 10 Figure 6 Once all entries are made press the Save Routes to Radio button to complete the Route Append programming of the Master Site The remote locations will a...

Page 31: ...figuration for serial PLC emulation modes the return path from the remote to the master must also be configured in the route and append tables If a repeater route is not used to communicate to a remot...

Page 32: ...rial Data Interface The Ethernet port on the 195M H C can be configured as the serial data interface SDI to be used by software applications to transport data The configuration and operation of this m...

Page 33: ...dable from http www java com The version required will be based upon your operating system Note The installation and updates from Java may try and install additional web browser toolbars Uncheck the o...

Page 34: ...e current configuration parameters for the modem will be displayed Figure 4 If the 195M H C information is not displayed press the Read Config button to continue The majority of the radio s configurat...

Page 35: ...listed were read from ESTeem address 184 using address 183 as a repeater 183 184 If the repeater routes are already defined for the network using the Route Append tables you can just enter the destin...

Page 36: ...Monitoring button is pressed a second time If multiple repeaters are required to access a remote or the Modbus monitoring is used on a busy network the Modbus Timeout parameter may need to be adjusted...

Page 37: ...gateway to access remote slave wireless requires slave to be in gateway append route tables reference http www focus sw com fieldtalk modpoll html Save and Load Configuration File The 195M H C s conf...

Page 38: ...ication is lost to the modem on reset you may have to press the Connect button to again see the command prompt CMD Diagnostics The diagnostic menu tests the wireless communication between multiple EST...

Page 39: ...the standard features you would find on a laboratory grade analyzer The following is a summary of the configuration parameters Center Frequency This frequency value can be entered with a keyboard or u...

Page 40: ...ime to turn it off MURS Frequencies Model 195M Only The FCC has set aside five frequency channels in the VHF band for Multi Use Radio Service MURS operation By operating on these frequencies and follo...

Page 41: ...ngth in diameter For the Model 195C 450 470 MHz this is approximately 6 5 inches A conducting surface can be anything from the rooftop of an automobile to a file cabinet Coax Cables To minimize signal...

Page 42: ...xWrap s bond begins to cure immediately upon contact with itself Repositioning or removal is not recommended after 2 minutes of wrapping 3 Apply an electrical coating sealing agent over the vapor barr...

Page 43: ...CHAPTER 7 ANTENNA SETUPS Revised 15 Feb 2017 7 3 ESTeem Models 195MHC...

Page 44: ...CHAPTER 7 ANTENNA SETUPS Revised 15 Feb 2017 7 4 ESTeem Models 195MHC...

Page 45: ...CHAPTER 7 ANTENNA SETUPS Revised 15 Feb 2017 7 5 ESTeem Models 195MHC...

Page 46: ...CHAPTER 7 ANTENNA SETUPS Revised 15 Feb 2017 7 6 ESTeem Models 195MHC...

Page 47: ...CHAPTER 7 ANTENNA SETUPS Revised 15 Feb 2017 7 7 ESTeem Models 195MHC...

Page 48: ...CHAPTER 7 ANTENNA SETUPS Revised 15 Feb 2017 7 8 ESTeem Models 195MHC...

Page 49: ...00 bps running in narrow band configuration Factory default off a_bctrl 1 4 This function selects the Rockwell Automation Allen Bradley DF1 controller protocol Full emulation is enabled with the PLC P...

Page 50: ...H C 1 6 25 kHz channel spacing 2 12 5 kHz channel spacing Factory default 2 12 5 kHz channel spacing connect r1 r2 r3 da This command performs the connect to a destination ESTeem This function support...

Page 51: ...ructs the modem to disable the acknowledgment request on the information packet This is used when the designation device will respond with its own acknowledgment Factory default off on Enabled off Dis...

Page 52: ...alled Model should be the same as product being used netmask IP Address Netmask The netmask command sets the IP netmask for the ESTeem 195M H C This command is used in conjunction with the ip_addr and...

Page 53: ...Protocol 3 Modbus ENC_RTU Protocol Configuration Protocol 4 ModbusTCP 5 Opto22 Protocol 6 Modbus ASCII 7 Rockwell Automation EthernetIP Reserved 8 Remote program 1 254 1 254 1 254 1 254 This command i...

Page 54: ...n of this command stores the current command values and switches Note Please wait approximately two seconds after executing the SAVE command before turning off power to the ESTeem s n Serial Number co...

Page 55: ...bles the telnet access to the radio for additional security Factory default on on Enabled off Disabled termt 0 5000 The serial device interface receive termination timer value This value is the time a...

Page 56: ...through one of the four RJ 45 ports in the front panel of the Model 195M H C Figure 1 During the configuration of the modem one of these ports is configured as the serial data interface SDI All data...

Page 57: ...3 and 4 The ESTeem Model 195M H C have two RS 232C data interfaces on the front panel Port 3 has a full RS 232 interface with handshake while Port 4 has only Transmit Receive and Ground Port 4 will g...

Page 58: ...Port 1 RS 485 or Port 2 RS 422 and the corresponding signal lines Figure 1 can be inserted in the screw terminals Note Verify the screw terminal cover is attached to the cable before termination 4 20m...

Page 59: ...o provide local signal strength RSSI information but cannot gather information from a Model 192 because the process uses ModbusTCP protocol only available in the 195M C The ESTeem Model 192 configurat...

Page 60: ...ility mode to communicate with an ESTeem Model 192 To configure for compatibility select the Model 192 Compatibility tab Figure 4 and set 192 Compatibility to ON This will set the software command 192...

Page 61: ...ch can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures 1 Re orient the radio TV receiving antenna 2...

Page 62: ...T technical support if you need assistance with calculations for various power levels antennas and minimum safe separation distances Terms P RF Power milliwatts Gi Antenna gain relative to isotropic G...

Page 63: ...ation Distance Controlled Environment FCC Minimum Separation Distance Uncontrolled Environment Industry Canada Minimum Separation Distance Uncontrolled Environment 195C 9 Watts Max AA19C 0 dBd 35 cm 0...

Page 64: ...6 25 KHz Channel Emissions Designator 4K37F1DDN Model 195M 12 5 KHz Channel Spacing 9 600 12 500 bps FCC Type Acceptance No ENPESTEEM195M 12 5 KHz Channel Emissions Designator 8K59F1D 6 25 KHz Channe...

Page 65: ...ns Office OR 2424 Edenborn Ave Suite 460 Metarie LA 70001 MARYLAND 1017 Geo Fallon Building 31 Hopkins Plaza Baltimore MD MASSACHUSETTS Boston Office BS 1 Batterymarch Park Quincy MA 02169 7495 MICHIG...

Page 66: ...ES All ESTeem 195M H C in the same wireless network must have the same encryption settings and keys passp Passphrase This software command will use the characters in the Passphrase to generate the AES...

Page 67: ...m External DC Power Input 10 8 to 15 VDC Input Output Connectors Ethernet Port 10 100 RJ 45 Female Serial Data Interfaces One of four selectable Baud Rates 2400 to 115 200 1 RS 232 Port 1 4 Wire Tx Tx...

Page 68: ...del No AA20C 1 Antenna Type Omni Directional DC grounded Collinear 5 8 wave over 1 2 wave Applications Fixed base or mobile mounting L shaped mounting bracket may be removed for panel mounting Ground...

Page 69: ...nce 50 ohms Gain 9 dBd VSWR 1 5 Front To Back Ratio 20 dB Horizontal Beamwidth 59 degrees Vertical Beamwidth 53 degrees Antenna Material High strength aluminum with gold chromate finish Mounting Hardw...

Page 70: ...ternal DC Power Input 10 8 to 15 VDC Input Output Connectors Ethernet Port 10 100 RJ 45 Female Serial Data Interfaces One of four selectable Baud Rates 2400 to 115 200 1 RS 232 Port 1 4 Wire Tx Tx Gnd...

Page 71: ...DC grounded Collinear 5 8 wave Applications Fixed base or mobile mounting L shaped mounting bracket may be removed for panel mounting Ground plane radials may be removed depending on application Frequ...

Page 72: ...ce 50 ohms Gain 8 dBd VSWR 1 2 1 Front To Back Ratio 12 18 dB Horizontal Beamwidth 80 degrees Vertical Beamwidth 58 degrees Antenna Material 250 6061 T6 Aluminum Mounting Hardware Heavy duty U bolts f...

Page 73: ...0 Watts RJ 45 Connector Cat 5 Cable 300 Ft Maximum External DC Power Input 10 8 to 15 VDC Ethernet Port 10 100 RJ 45 Female Serial Data Interfaces One of four selectable RJ 45 Female Antenna Input Out...

Page 74: ...nnector UHF Female SO 239 Antenna Envelope 43 in length with 43 in width with ground plane radials Weight 2 lbs Model No AA202H Antenna Type Directional 6 element yagi Applications Fixed base mounting...

Page 75: ...MHz Polarization Vertical Impedance 50 ohms Gain 5 0 dBd VSWR 2 0 Front To Back Ratio n a Horizontal Beamwidth n a Vertical Beamwidth 18 degrees Antenna Material Heavy duty fiberglass radome with a th...