CHAPTER
6
UTILITIES
&
FEATURES
Revised: 15 Feb 2017
6-3
ESTeem Models 195MHC
The
Advanced
Configuration
tab
will
allow
you
direct
access
to
any
of
the
individual
software
commands
in
the
ESTeem
195M,
195H
or
195C.
The
following
sections
describe
the
individual
tabs
and
how
they
are
used.
Read
Configuration
The
195
Series
Narrow
Band
Configuration
Tool
provides
a
graphical
interface
to
the
individual
software
commands
for
the
ESTeem
195C
or
195M.
On
the
Configuration
tab
the
software
commands
can
be
displayed
by
their
category.
All
‐
Display
the
status
of
all
software
commands
(Figure
5)
Change
–
Display
commands
changed
from
factory
default
Network
–
Ethernet
network
commands
Interface
–
Port
configuration
commands
PLC
–
PLC
emulation
commands
Radio
–
Radio
configuration
commands
Pressing
the
Read
Config
button
with
any
of
the
above
radials
selected
will
display
the
commands
associated
with
the
selection.
Read
Remote
195C
or
195M
Configuration
The
software
commands
can
read
in
the
same
way
from
a
remote
ESTeem
195M/H/C
through
the
wireless
network.
A
direct
path
entry
or
repeater
route
can
be
used
to
read
the
configuration.
For
example
in
Figure
7,
the
commands
listed
were
read
from
ESTeem
address
184
using
address
183
as
a
repeater
(183,184).
If
the
repeater
routes
are
already
defined
for
the
network
(using
the
Route/Append
tables),
you
can
just
enter
the
destination
address
and
check
the
Use
Route
from
Append
Table
check
box.
Write
Configuration
Any
software
command
displayed
after
reading
the
configuration
can
be
modified.
Once
the
commands
have
been
changed,
press
the
Write
Config
button.
The
modem
will
save
the
changes
and
reboot.
The
wire
configuration
can
also
be
sent
through
repeaters.
For
example
in
Figure
7,
the
commands
listed
were
written
to
ESTeem
address
184
using
address
183
as
a
repeater
(183,184).
If
the
repeater
routes
are
already
defined
for
the
network
(using
the
Route/Append
tables),
you
can
just
enter
the
destination
address
and
check
the
Use
Route
from
Append
Table
check
box.
Reset
Unit
Pressing
the
Reset
Unit
button
performs
the
same
action
as
pressing
the
Reset
button
on
the
face
of
the
195M/H/C.
The
modem
will
discard
any
unsaved
commands
and
read
the
program
from
the
non
‐
volatile
memory.
This
can
be
performed
on
a
remote
ESTeem.
Factory
Defaults
Pressing
the
Factory
Defaults
button
will
reset
the
software
commands
to
factory
default
settings
(see
Appendix
A
for
all
default
values).
Factory
defaults
does
not
reset
address,
frequency
or
squelch
settings.
Figure
5:
Advanced
Configuration
menu
Summary of Contents for 195C
Page 43: ...CHAPTER 7 ANTENNA SETUPS Revised 15 Feb 2017 7 3 ESTeem Models 195MHC...
Page 44: ...CHAPTER 7 ANTENNA SETUPS Revised 15 Feb 2017 7 4 ESTeem Models 195MHC...
Page 45: ...CHAPTER 7 ANTENNA SETUPS Revised 15 Feb 2017 7 5 ESTeem Models 195MHC...
Page 46: ...CHAPTER 7 ANTENNA SETUPS Revised 15 Feb 2017 7 6 ESTeem Models 195MHC...
Page 47: ...CHAPTER 7 ANTENNA SETUPS Revised 15 Feb 2017 7 7 ESTeem Models 195MHC...
Page 48: ...CHAPTER 7 ANTENNA SETUPS Revised 15 Feb 2017 7 8 ESTeem Models 195MHC...