15
22. Set the parameters to match the needed settings. Press/release the SET button
to access the parameters. Press/release the ADD or DEC buttons to review or
change the individual parameter settings. Press/release the SET button to move
to the next parameter.
P1 is setting pull or push to open
.
00 = Push to open, 01 = Pull to open
P2 is setting primary leaf force
.
The lower the number the easier the gate will re-
verse directions when it meets resistance. This number may have to be changed to a high-
er setting if your gate is obstructing unexpectedly. The number should be set to the high-
est number during initial setup and reduced to the point of reliable operation that takes
into account change in gate resistance through out the year. The options are 0-32.
P3 is setting secondary leaf force
.
Note: this parameter will only show if Dip Switch
2 is UP.
The lower the number the easier the gate will reverse directions when it meets
resistance. This number may have to be changed to a higher setting if your gate is ob-
structing unexpectedly. The number should be set to the highest number during initial
setup and reduced to the point of reliable operation that takes into account change in gate
resistance through out the year. The options are 0-32.
P4 is setting a delay between leafs
if you have overlapping gates or a gate lock.
Note: this parameter will only display if DIP Switch 2 is UP.
The motor wired into the
primary terminals (1) open first if there is a delay and closes second. It is recommended
to have a delay of 3 seconds to avoid any jamming issues between leafs.
P5 is release time for the gate lock.
Note: this parameter will only display if DIP
Switch 3 is UP and professional board is installed.
This option determines the length of
time 12VDC will be sent out of terminals E_LOCK. The options are 1-4 seconds.
P6 is delay for automatic re-close from the open position.
Note: this parameter
will only display if DIP Switch 1 is UP.
This option needs to be turned on using the
dip switch on the board. The options are 0-99 seconds.
23. Program remote transmitters to the board. Press/
release the learn button. Learn LED will illuminate.
24. Press/hold a button on a remote transmitter until the learn
LED flashes.
Repeat step 24 with other buttons on the remote or buttons on
other remotes.
NOTES ABOUT REMOTES:
You can program up to 400 codes into the receiver. This could mean 1 button on
400 different remotes or this could mean all 4 buttons on 100 remotes or anything
in between. Some choose to program all 4 buttons to a single receiver if they are
not using multiple gates to eliminate pressing the incorrect button on the remote.
To do so follow the programming above with each button of the remote. You can
erase all programmed codes by holding Learn 1 until the Learn LED comes ON
and then turns OFF.
25. The gate opener is now installed and operational via remote transmitter. Please
review the troubleshooting / control board overview
section following this page for more information on your gate opener. Also review
this area for more information on optional accessory