16
of 34
V 1.0
www.esavep.com
5.4 Specifications
Note: Test Conditions:
Ambient temperature : 20
°
C Water inlet 15
°
C, Water Outlet 55
°
C
Working conditions: -7 to 43
°
C
Maximum water temperature storage: 60
°
C
Water temperature range: 12
°
C -60
°
C
Water pressure operating range 0.1-.07MPa
5.5 PERFORMANCE
5.5.1 Performance Assumptions
Heating Capacity
The unit absorbs energy from the air taken in through the inlet ductwork. If the air inlet temperature is
low, heating capacity will show a variation from standard conditions.
3 Minutes Protection
When the unit stops, if you try to restart the unit (or turn the unit on manually) immediately, the unit will
not run for 3 minutes. This is built in protection for the compressor.
Model
ECOCENT 250 T
ECOCENT 250 T2
Heating capacity
kw
3
3
Water tank volume
L
250
250
Power input
W
790
790
Running current
A
3.6
3.6
Power supply
V/Ph/Hz
220-230/1/50
220-230/1/50
Compressor number
1
1
Compressor type
Rotary
Rotary
Rated outlet water temperature
℃
55
55
Max outlet water temperature
℃
60
60
Air volume
M
3
/h
450
450
Air pressure
Pa
60
60
Duct diameter
mm
Φ150
Φ150
Noise
dB(A)
49
49
Water inlet size/outlet size
inch
G 3/4"
G 3/4"
Net dimensions
mm
Φ640×1610
Φ640×1610
Package dimensions
mm
705×705×1750
705×705×1750
Net weight
kg
84
88
Gross weight
kg
103
107