will allow the Ecocent to operate efficiently (the inlet air should not be below 7° C or above 43° C).
The optional secondary coil in the Ecocent (25T2 model) enables direct connection to a second stable
heat source, e.g. a solar heating system or a boiler.
Under no circumstances is the Ecocent to be installed onto an
uncontrolled heat source e.g wood burner or back boiler
Picture 1
Dehumidification – The Ecocent can be used to dehumidify rooms that are hot and damp – e.g. Laundry
Rooms (See Picture 2). The unit is equipped with a condensate drain that must be properly directed to a
suitable waste pipe where the condensate water (non acidic) can drain away. If the drain is into a main sewer
it must have a trap installed to prevent back smell through the Ecocent.
Picture 2
Cooling in the re-circulating air mode (picture 3)
The Ecocent can extract warm air and place cooled, dehumidified, outlet air back into the same room –
this is perfect for cellars and gymnasiums. Any cold air exhaust air ducting must be lagged when
passing through a warmer area to prevent the formation of condensate. All ducting should be 150mm or split
into two 75-80mm ducts.
Picture 3