18
Kongsberg C-series
The Start pushbutton is active when the Mode selector switch is set to
the Auto position.
When the gantry is in position over the pallet, pressing the Start
pushbutton will cause the i-BF to pick a board and deliver the board to
the table.
When “Hold at Place Position” is enabled, the suction cups will hold
the board on the support table. Pressing the Start pushbutton will
cause the Gantry to release the board and to return to Home position.
5 - Fault Reset pushbutton
The Fault Reset pushbutton is a blue lighted pushbutton.
The Fault Reset button will flash whenever the i-BF is in a faulted
condition.
A faulted condition means the i-BF safety circuit is de-energized and
the i-BF is in a safe condition.
The i-BF will not operate in any mode when the safety circuit is de-
energized as indicated by the flashing blue light.
Pressing the Fault Reset button will cause the safety circuit to be reset, providing there are no
active machine faults.
The blue light will stop flashing when the i-BF safety circuit is reset.
6 - Tapeswitch Bypass Pushbutton
There may be occasions where a safety bumper is pressed and cannot be released due to a
mechanical jam.
The safety system cannot be reset when a safety bumper is pressed.
The Tapeswitch Bypass pushbutton allows the safety bumper system
to be bypassed to allow the i-BF to be jogged out of the mechanical
jam situation.
The Tapeswitch bypass feature is only operational while a safety
bumper is pressed.
During a bumper actuated jam, pressing the Tapeswitch Bypass
pushbutton will cause the safety bumper system to be bypassed for a
period of 15 seconds.
This bypass allows the operator to reset the safety circuit and jog the i-BF out of the jammed
condition.
The Tapeswitch Bypass Pushbutton is located on the electrical enclosure door.
201