19
Kongsberg C-series
The vacuum level is expressed in mmHg.
Monitoring the vacuum level during board picking can be helpful in troubleshooting the stacker for
proper board picking.
For example, low vacuum during picking may be a sign that not all of the plenums made contact with
the cut board before the carriage began raising the board.
10.1.8 - Servo Fault Codes
A fault code will be displayed in the event that any of the stacker servos become faulted.
The fault code can be looked up in the “Kollmorgen AKD PDMM Fault Card EN Rev F.pdf” document
that is provided at the end of this document.
10.1.9 - Feeder button
The Feeder button will advance you to the Feeder control screens.
The Feeder control screens are very similar in layout and function to the Stacker control screens.
19.10.2. Jog Functions Screen
The Jog Functions screen allows the operator
to enable jogging of the vertical carriage beam
UP/Down and the horizontal Gantry Forward/
Reverse using the Jog selector switch on the
control console.
The machine Mode selector switch must be
set to Manual in to enable the jog features.
When enabled, the round circle associated
with the screen button will be green. Switching
back to Auto mode automatically cancels the
enabled Jog Functions.
19.11. Starting Up the Feeder and Stacker for Daily
Operation
The system can be powered OFF when not in use by pressing the red Power OFF pushbutton
located on the door of the feeder electrical enclosure, and/or by switching off the main power
disconnect.
Feeder/Stacker Main Disconnect Power ON
249