Software
6.1.3.4 Test Data Transfer
Click the
Reload I/O Devices
button to switch into
Free Run
state (see upper menu bar):
Fig. 17:
TwinCAT
Reload I/O Devices
button
The dialogue
Activate Free Run
opens and has to be confirmed. Make sure that all slaves are in
“OP” state:
Fig. 18:
TwinCAT tab
Online
If the states are
Operational
In case of problems please check the outputs in the EtherCAT Workbench and read the following
note.
INFORMATION
The most probable reason of the problem that might occur here is that different
configurations for primary and secondary side have been created at the configuration of
the variables. In this case the ECX-EC does not switch into
Operational
or
Safe-
Operational
(with error
Inconsistent Settings
–
Al Statuscode
0x0026).
Make sure that the input variables of the primary side comply with the output variables
of the secondary side and vice versa (the name of the variables can be disregarded).
ECX-EC
Manual • Doc. No.: E.3022.21 / Rev. 1.9
Page 31 of 74