SECTION 3
PCM-875A Mechanized Plasma Cutting System
Installation
3-17
6.Tighten heat shield fully to hold the parts in firm
contact with each other and to the torch head.
“Fully” means at least 5mm rotation after electrode
seat contacts electrode holder.
7. After retainer/heat shield is tightened, try to
rotate the nozzle with your finger tips. If it rotates,
the sealing of components is not tight enough and
will likely leak gas.
NOTICE
See “Section 6 – Maintenance” for torch
lead installation or replacement.
CAUTION
!
IMPORTANT: See Maintenance section.
Follow all instructions in the booklet
packed with your unit. DO NOT install or
attempt to operate this torch without
following these instructions.