SECTION 5
PCM-875A Plasmarc Cutting System
Maintenance
5-2
5.1.2 Inspection and Cleaning
A
C
B
D
F
F
F
F
F
E
E
Frequent inspection and cleaning of the PCM 875A
system is recommended for safe and proper
operation.
A. Check work cable for secure connection to
workpiece.
B. Check safety earth ground at workpiece and
at power console chassis.
C. Check heat torch heat shield. Replace if
damaged.
D. Check torch electrode and cutting nozzle for
wear at least once per 8 hours operation.
E. Ensure cable and hoses are not damaged
or kinked.
F. Ensure all plugs, fittings and ground
connections are tight.
WARNING
!
Wear safety eye protection when
using compressed air.
Serious eye injury may result.