7 FUNCTION EXPLANATIONS
0460 949 474
- 30 -
© ESAB AB 2021
Travel axis and wire axis
Set travel axis and wire gearing by performing the same procedure as for product code
external axis.
Setting menu
Here you can set travel speed and direction, start data and limits can be used for travel
speed.
SAW WELD DATA SETTING
TRAVEL SPEED
DIRECTION
START DATA►
SETTING LIMITS►
MEASURE LIMITS►
30 cm/min
■
MEASURE
QUIT
Start data menu
Flux/Gas pre-flow is active if the chosen start type is scratch. Start signal (relay output 2) will
be generated, and when pre-flow time has elapsed travel will start. When start type direct is
chosen, pre-flow has no function.
SAW START DATA
FLUX PREFLOW
START TYPE
0.0 s
DIRECT
MEASURE
QUIT
Scratch start will start a travel and generate start signal out at the same time when the start
button is pressed. Pre-flow has no function.
When starting relay output 2, a direct start will be generated, but travel will not start until
digital input for current flow is active. So if no input on I/O ATAS for current flow, use scratch
start instead.
SAW START DATA
FLUX PREFLOW
START TYPE
0.0 s
SCRATCH
MEASURE
QUIT
Measure menu
In the measure menu, you can see measure values for travel speed and jog wire speed. The
wire motor is not started when you press the start button on the PEK control unit, but you can
use that motor for other work. In the setting menu, you can also set travel speed.