7 FUNCTION EXPLANATIONS
0460 949 474
- 29 -
© ESAB AB 2021
7.29
Control parameters
In some applications the function Control parameters is displayed instead of Dynamic
control. There are two settings to make under Control parameters:
•
DYNAMICS
- Affects the dynamic characteristics
•
INDUCTANCE
- Higher values give a wider weld pool and less spatter. Lower values
produce a stable, concentrated arc and a harsher sound.
• Control parameters are selected in the weld data setting menu.
7.30
Setting limits
For information about setting limits see section "Setting limit editor".
7.31
Measure limits
For information about measurement parameters see section "Measure limits editor".
7.32
PEK control unit as separate motor control
PEK as motor control without a power source is used when you want to have a travel control
and possibility to give a start signal to an external power source. Remote is also active via
ATAS I/O so you can control a roller bed with relay out for the start and an analogue
reference for speed.
Activate motor control
To activate the motor control function set
PRODUCT CODE
to
MOTOR CONTROL
. The
supervision by the power source is now disabled.
MACHINE CONFIGURATION
PRODUCT CODE
WIRE FEED AXIS►
TRAVEL AXIS►
TANDEM►
PARALLEL POWERSOURCES►
ICE WIRE FEED►
NODE ID SETTINGS►
SYSTEM INFORMATION►
Motor control
OFF
QUIT
A6TF F1
MTW600
FREE 2 AXIS
FREE 3 AXIS
N7500I
Motor control