E
N
G
L
IS
H
33
4. Adjusting the sensitivity (default: 4)
This menu allows the sensitivity of the device, when the door encounters an obstacle, to be increased or decreased.
This parameter is already set to a mid value (4) that should be ideal for the majority of installations.
3. Self learning of the forces
Press the
-
key,
the display shows
3
Press the
key:
3
flashes - the door opens
When the door stops, press
the
key to confirm.
Press the
key once more
to continue - the door closes
When the door stops, press the
key to save the settings.
The display shows
3
Press the
-
key,
the display shows
4
Press the key
:
0
flashes
Select the desired level using the
+
and
–
keys
m
PLEASE NOTE: On completion of the procedure, it is possible to exit the programming procedure, storing the parameters
set: press and hold the
key for 5 seconds until the segments of the display illuminate one at a time until showing
0
m
PLEASE NOTE: if this parameter is modified, then on completion of programming, it is
necessary to conduct a complete open/close cycle, during which the control unit automatically
conducts a fresh force training operation (during this cycle, the motor works at maximum force,
so particular attention must be paid).
Press the
key to save
the settings: the display
shows
4
2. Setting the close limit switch
Press the
-
key,
the display shows
2
Press the
key:
2
flashes
Press and hold the
+
(the door opens)
or
-
(the door closes)
key to reach the fully
close position
When the door reaches the
closed position, wait 2
seconds, then press the
key to save the settings