ARES electro-mechanical operator
27
DESCRIPTION OF THE PRODUCT
1
ELEMENTS OF THE COMPLETE INSTALLATION
Fig. 1
Elements of the complete installation
The safe and correct operation of the
installation is the responsibility of the installer.
For greater safety, Erreka recommends installing the
photocells (3) and (8).
INSTALLATION COMPONENTS:
1
Operator
2
Flashing light
3
Exterior photocells
4
Key switch
5
Wall pushbutton
6
Switchboard
7
Connections box
8
Interior photocells
9
Electrolock
10
Stop on closing
11
Antenna
We recommend using the VIVO-M201(M) or VIVO-M101(M) switchboard for the 125/230VAC models
and the VIVO-D201(M) switchboard for the 24VDC models.
ELECTRICAL CABLING:
Element
Nº wires x section
Maximum length
A: Main power supply
3x1.5mm
2
30m
B: Flashing light
2x0.5mm
2
20m
C: Photocells (Tx / Rx)
2x0.5mm
2
/ 4x0.5mm
2
30m
D: Pushbutton or key switch
2x0.5mm
2
25m
E: Operator (125/230 VAC)
4x1mm
2
20m
E: Operator (24VDC)
2x1mm
2
8m (maximum 25m with cable 2x2.5mm
2
)
F: Antenna
Coaxial cable 50
k
(RG-58/U)
5m
Summary of Contents for ARES AE3324D
Page 2: ......
Page 4: ......
Page 16: ...Actualizado 8 3 16 MANTENIMIENTO Y DIAGN STICO DE AVER AS 12 Manual de instalaci n...
Page 28: ...Mis jour 9 4 16 MAINTENANCE ET DIAGNOSTIC DE PANNES 24 Manuel d installation...
Page 40: ...Updated 9 4 16 MAINTENANCE AND DIAGNOSIS OF FAILURES 36 Installation Manual...
Page 52: ...Actualizado 9 4 16 MANUTEN O E DIAGN STICO DE AVARIAS 48 Manual de instala o...