DigiOpG2
Digital Video Recorder
Page
30
3040-00052
6.1.2.
Page Sequence
Set sequencing period when automatic screen sequencing mode is selected in real time live mode. Page Sequence indicates
switching over from selected screen to the next screen in fixed period of time. For example, Page Sequence is operated in 4-
split screen, the next screen (5-8 channel, 9-12 channel, 13-16 channel) is displayed after certain fixed period of time. This
status can be on/off by pressing the [SEQ] button on the system front panel or IR remote controller. Possible setting range is
1~60 seconds, and the default is 3 seconds.
6.1.3.
IR Remote ID
Set IR remote controller ID. To operate the system easily using IR remote controller, IR remote controller ID should be set first.
The setting procedure of IR remote controller ID is shown below.
1.
Insert battery in IR remote controller. (AAA Size ×2)
2.
Press [SCR / CH] and [F/O/E] button on the IR remote controller at the same time.
3.
Check if the LED on IR remote controller is lighted.
4.
Press two-digit number (01~99) to set IR remote controller ID.
5.
Assign the identical ID number using front panel arrow keys on the system.
6.
Save the ID by pressing [Save] button on the screen.
Note
Setting the IR remote controller ID is necessary only once after purchasing the system.
Note
All systems manufactured in the factory have identical ID as initial value. Therefore, one IR remote controller can
control several systems when using the initial value. To protect such circumstances, it is recommended to set
different ID for each system. Since ID change on the IR remote controller is easy, it is convenient to operate several
systems separately by changing the ID using one remote controller.
6.1.4.
P/T/Z Protocol
Set the protocol to control the P/T/Z controller connected to P/T/Z port on the back panel. P/T/Z controller is also called receiver
or RX if it becomes separated from camera. Default is NONE, which indicates that the P/T/Z controller protocol is not set.
Protocol currently supported is shown below.
1
ERNITEC
2400 baud rate
no parity
8bit
1 stop bit
2
Panasonic
19200 baud rate
no parity
8bit
1 stop bit
3
Pelco P
4800 baud rate
no parity
8bit
1 stop bit
4
Pelco D
2400 baud rate
no parity
8bit
1 stop bit
5
Sensormatic
2400 baud rate
no parity
8bit
1 stop bit
6
Smart Scan
9600 baud rate
even parity
8bit
1 stop bit
7
VC_C4
9600 baud rate
no parity
8bit
1 stop bit
8
Vicon
4800 baud rate
no parity
8bit
1 stop bit
Set the controller address correctly for each channel after setting the protocol.
6.1.5.
Spot-Out Dwell
Set the switchover period of the Spot-Out channel to 1~60 seconds.