GB-26
D
GB
NL
RUS
PL
F
E
UA
CN
1
17
21
2
12
13
6
3
23
24
16 25 15 22 9
11
10
8
7
14
5
4
20
19
18
Item
Order number
Designation
1
N70400015
Air inlet seal, D 98 (RGA 100 flue gas seal)
2
N70400014
Air inlet pipe
3
N70400015
Fan air inlet seal, D 70
4
N70000082
Burner fan
5
N50280116
Combination control CG 2
6
N50820041
Pipe coupling, straight, brass
7
N50260024
Motor relay
8
N51600011
Relay socket for RGA 100 ACU
9
N70000037
Air pressure switch
10
N52800034
Capacitor for RGA 100
11
N50260109
Ignition transformer
12
N70400006
Pipe elbow, air
13
N70000031
Air outlet seal (square hole)
14
N70400016
Upper hinge pin (pivot + screw) for RGA 100
15
N70300005
ACU 121, complete
16
N50280136
Gas inlet pipe
17
N70400007
70 – 100 air inlet reduction
18
N70400008
Air outlet seal, D 49
19
N70400009
Air outlet pipe
20
N70400010
Gas outlet pipe
21
N50390117
Pressure test point
22
N70400001
Burner Chip Card (BCC) for RGA 100 ACU
23
N70400011
Ionization cable kit
24
N70400012
Ignition cable kit
25
N70400013
Cable harness for RGA 100 ACU
Technical data
Gas types: II2ELL3B/P,
natural gas H at 20 mbar and natural gas L at
25 mbar (gases of category 2);
LPG (gaseous) at 30 – 50 mbar (gases of
category 3): propane, propane/butane, butane.
Fused with 16 A.
NOx Class: depending on gas type up to Class 5.
Max. inlet pressure p
u
: 70 mbar.
Resistant to high-pressure cleaning.
Gas connection: Rp ¾ to ISO 7-1.
Staged control: On/Off signal (240 V AC or
24 V AC/DC via coupling relay).
Continuous control: capacity control from
60 – 100% (0 – 10 V/0 – 20 mA actuating signal).
Max. efficiency: 100 kW = 93%, 60 kW = 96%.
Burner control unit with direct spark ignition and
ionization control.
Fan type:
main fan: axial, burner fan: radial.
Material:
housing: stainless steel,
heat exchanger: stainless steel,
burner control unit: flame-retardant polymer blend
made of polycarbonate (PC) and acrylonitrile
butadiene styrene copolymer (ABS).
RGA100_NF.indd 26