Checking the usage
RGA 100 ACU
Heater with indirect combustion for animal sheds
and horticultural greenhouses. Depending on the
type and setting, the heater can be operated with
natural gas or LPG (propane/butane).
This function is only guaranteed when used within the
specified limits – see page 26 (Technical data). Any
other use is considered as non-compliant.
Type code
Code
Description
RGA 100
Heater
Part designations
MODE
RESET
ON/OFF
1
4
7
2
5
3
6
1
Stainless steel housing RGA 100 ACU
2
Housing cover with burner control unit ACU
(service form in housing cover)
3
Operating box
4
Service flap
5
Connection for gas combination control
6
Connection for chimney with condensate vessel
(not included in the delivery)
7
Main fan
Type label
Air circulation, electrical connection rating, rated heat
input, gas type, category, supply pressure, burner
pressure, enclosure: see type label.
Ademco 2 GmbH, Hansastrasse 6
49504 Lotte (Büren)
Gemany
012-18
0085 20
•
Before installation, check whether the device is
suitable for the regional gas type and the speci-
fied limits, see type code and page 26 (Techni-
cal data).
Installation
DANGER
Danger of death! Gases are generated during the
storage of slurry which remain partly dissolved in
the liquid. If the slurry is strongly agitated during
mixing and purging, poisonous, explosive gases
such as hydrogen sulphide and methane are re-
leased. If an ignition source is present, the released
gas can explode.
To avoid damage during operation, please observe
the following:
– Switch off the heater before mixing and purging
the slurry.
– Close the slide valves when storing slurry out-
side.
– The fan for the air supply must not be part of a
closed pipe system.
– Respect the safety distance of the heater to
inflammable materials, see “Installation position”.
– Consult your fire insurance provider and/or local
fire protection engineer to assess the foresee-
able, general risk of fire.
– For cleaning, care and maintenance, note the
applicable national regulations and directives.
– No condensation permitted. Comply with ambi-
ent temperature, see page 26 (Technical data).
Installation position
▷
Installation in the horizontal position.
▷
Note the safety distance to walls and inflam-
mable materials.
> 3 m
> 1 m
> 0,2 m
> 0,5 m
> 0,5 m
▷
Ensure sufficient free space around the device.
There must be no obstructions in front of the inlet
and outlet side of the heater.
▷
The distance between the heaters should be
greater than 30 m.
▷
To avoid overheating, do not cover the main fan.
RGA100_NF.indd 2