Environmental Capabilities
Table 13
Environmental Parameters
Unit
Value
Normal Cond.
Non destruct.
Temperature
C
-33 - +55
-40 - +70
Relative humidity
%
5 - 100
5 - 100
Absolute humidity
g/m
3
0.26 -40
0.26 - 40
Change of temperature
C/min
6
6
Rain temperature
C
5
5
Vibration sinus:
displacement
mm
3
acceleration
m/s
2
10
frequency
Hz
2 - 9
9 - 200
Vibration random:
ASD
m
2
/s
3
0.5
0.2
frequency
Hz
2 - 200
200 - 500
Shock:
peak acc.
m/s
2
100
1)
duration
ms
11
Fauna
none
Not Appl.
Not Appl.
1)
The requirements belong to ’Safe function’ with the exemption:
performance of the RBS shall be verified as ’no loss of calls’
EN/LZT 720 0008
P2A
2001-11-28
31 (485)
© Ericsson Radio Systems AB
— All Rights Reserved —
P
re
li
m
in
a
ry
Summary of Contents for RBS 2106