Radio Configurations, RBS 2106 and RBS 2206
Table 20
3 x 4 and 3 x 2 configurations with CDU-G
Cell
CDU
ASU Connector
TMA
Antenna
No. / Connector
(Co-siting only)
No. (TMA config.
only)
1
1 / TX / RX1
1
1
TX / RXA
1 / TX / RX2
2
2
TX / RXB
2
2 / TX / RX1
4
4
TX / RXB
2 / TX / RX2
3
3
TX / RXA
3
3 / TX / RX1
6
6
TX / RXB
3 / TX / RX2
5
5
TX / RXA
Table 21
1 x 8 configurations with CDU-F
Cell
CDU
TMA
Antenna
No. / Connector
No. (TMA config. only)
1
1 / TX / RX
1
TX / RXA
1 / TX / RX
3
TX / RXB
Alt. 1
3 / TX / RX
3
TX / RXA
3 / TX / RX
5
TX / RXB
Table 22
1 x 8 configurations with CDU-G
Cell
CDU
ASU Connector
TMA
Antenna
No. / Connector
(Co-siting only)
No. (TMA config.
only)
1
1 / TX / RX1
1
1
TX / RXA
1 / TX / RX1
3
3
TX / RXB
Alt.1
3 / TX / RX1
3
3
TX / RXA
3 / TX / RX1
5
5
TX / RXB
Note:
It is only possible to have one 1 x 8 configuration in the
cabinet. One 1 x 8 configuration can be combined with one
1 x 4 configuration.
4.6
Site Cell Configurations (SCC)
The following section shows SCCs in one RBS. More RBSs can be
combined to form larger configurations at a site. Possible expansions,
where different RBSs are connected using TG-synchronization, are
described in Section 4.7 on page 78.
The following SCCs are supported by the RBS:
•
specified basic radio configurations
•
the RBS with any number of dTRUs within the specified range
inserted in the specified position order.
EN/LZT 720 0008