Command Line Interface
Example
To configure port 1 as the working channel, with APS channel 1:
EXN400(config-flvr)# port 1 working 1
2.12.4
Gigabit Ethernet Specific Commands
2.12.4.1 pingtest
Description
This command is used to define default settings for ping.
Syntax
pingtest timeout period
timeout
Specifies the timeout for an expected response to
a ping echo request. Unit is tenth of a second.
Valid range is [1-256]. Default value is 10.
period
Specifies the delay between 2 retries. Unit is tenth
of a second. Valid range is [1-256]. Default value
is 10.
Default
10 10
Modes
Failover configuration
Example
To set default timeout and period to 20 tenths of a second:
EXN400(config-flvr)# pingtest 20 20
2.12.4.2 port
Description
This command is used to configure a port as a failover
channel in the failover group.
Syntax
port portNum {working|protection}
[pingtest on ipAddr [t [p]]]
or
port portNum pingtest off
or
no port portNum
portNum
Specifies the port number.
working
Defines this port as a working channel.
protection
Defines this port as the protection channel.
ipAddr
Specifies the IP address to ping, in the dotted
format.
1553-LZY 214 2655 C 2004-11-24