Command Line Interface
Table 5
OAM-Related Statistics-PVC
Name Description
Rx Host frames
Terminated frames
Rx Iw frames
Interworked (bridged, routed, etc.) frames
Aborted frames
Aborted AAL5 frames
Clp frames
Number of frames with CLP bit set
Rx errors
CRC
CPI
Size
RAS
Underflow
Max
SDU
Iw max MRU
Iw
underrun
Number of errored frames, discarded due to:
AAL5 CRC error
Common Part Indication errors
Illegal pad field or length error
Reassembly timeout error
Underflow in receive buffer queue
Maximum Service Data Unit exceeded
Maximum Data Unit exceeded
Buffer shortage in interworking queue
Tx frames
Total number of transmitted frames
Example
To display OAM inforamtion for the current PVC:
EXN400(config-if-atm)# show stats
Displayed information include the following:
Table 6
OAM-Related Inforamtion-PVC
Name Description
Defect state
Defect state
AIS
End-to-end AIS state
Seg-AIS
Segment AIS state
RDI
End-to-end RDI state
Seg-RDI
Segment RDI state
Continuity Check
End-to-end continuity check state. It can be:
Activation in progress
Deactivation in progress
Not active as sink if feature is not active
FAILED–The printed delay represents the
period during which no CC cell has been
received
SUCCEEDED–The printed delay represents the
period during which CC cells have been
received
Seg. Cont. Check check
Segment continuity check state. It can be:
Activation in progress
Deactivation in progress
Not active as sink if feature is not active
FAILED–The printed delay represents the
period during which no CC cell has been
received
SUCCEEDED–The printed delay represents the
period during which CC cells have been
received
Perf. Monitoring
Performance monitoring state. It can be:
60
1553-LZY 214 2655 C 2004-11-24