Content
Page 8 of 159
15.1.3
User Maintainable Parts of the Analyzer ..................................................................................... 121
15.2
Maintenance Programs of the Analyzer ....................................................................... 122
15.2.1
Cleaning the Shear Valve ............................................................................................................. 123
15.2.2
Cleaning the Washing Head ......................................................................................................... 127
15.2.3
Cleaning the Measuring Chambers (Hard Cleaning) .................................................................... 128
15.2.4
Daily Cleaning .............................................................................................................................. 128
15.2.5
Special Cleaning Procedure .......................................................................................................... 128
15.2.6
Replacing Reagents ...................................................................................................................... 129
15.2.7
Disposal of Reagent Containers ................................................................................................... 130
16
Reagent Locking .................................................................................................. 131
17
The Daily-Routine ................................................................................................ 132
18
Troubleshooting .................................................................................................. 134
18.1
Software error messages ............................................................................................ 134
18.2
Pneumatic error messages .......................................................................................... 134
18.3
Mechanical Problems .................................................................................................. 135
18.4
Sample Rotor (SR) Failures .......................................................................................... 135
18.4.1
SR Gives Grinding Noise And / Or SW Displays SR Error Messages ............................................. 135
18.4.2
SR Error Appears During Initialization Process: ........................................................................... 136
18.4.3
The SR Does Not Turn Into the Analyzer Even With Open Front Panel ....................................... 136
18.5
Needle Mechanics, Vertical Motor (Mvert) Problems ................................................... 136
18.5.1
The Needle Carriage Keeps Dropping Back (Down) At Initialization ............................................ 136
18.6
Shear Valve (SV) Related Errors ................................................................................... 136
18.6.1
SV Error at the First Startup ......................................................................................................... 136
18.6.2
Grinding Noise after SV Cleaning, (after SV Reinstallation) ......................................................... 136
18.6.3
SV Leakage ................................................................................................................................... 136
18.7
Dilutor Errors .............................................................................................................. 137
18.8
Priming Problems ....................................................................................................... 137
18.8.1
The Analyzer Would Not Prime Liquids ....................................................................................... 137
18.9
Electronics Related Problems ...................................................................................... 137
18.9.1
No Image on Display, No Backlight .............................................................................................. 137
18.9.2
Touch Sensitive Surface Not Working .......................................................................................... 137
18.9.3
Touch (Click) Is Inaccurate ........................................................................................................... 137
18.9.4
The Cursor Seems To Be Moving With Good Ratios, But In a Smaller Area ................................ 137
18.10
The Analyzer Does Not Power On ............................................................................ 137
18.11
I2c Errors Displayed At Startup ................................................................................ 137
18.12
Measurement results related problems ................................................................... 138
18.12.1
Fluctuating PLT background values .............................................................................................. 138
18.12.2
Long, smeared population ........................................................................................................... 138
19
Accessories .......................................................................................................... 139
20
Appendices .......................................................................................................... 140
20.1
Reagent Consumption ................................................................................................ 140
Summary of Contents for ELite 5
Page 13: ...ELite 5 User Manual Page 13 of 159 Figure 1 ELite 5 with Autosampler Space Requirements...
Page 27: ...ELite 5 User Manual Page 27 of 159 Figure 9 4DIFF Scatter Diagram...
Page 142: ...ELite 5 User Manual Page 142 of 159 20 3 Printed Report Formats...
Page 143: ...ELite 5 User Manual Page 143 of 159...
Page 153: ...ELite 5 User Manual Page 153 of 159 20 5 Fluidic System...