7
8
Test Mode
After self-testing the Sensor automatically enters into Test Mode for 3 minutes and will
detect movement every 10 seconds.
Note:
To activate
test mode
at any time press the Test Button.
Power Saving Mode
Sleep after detecting human movement twice.
3 minutes later
No human movement within 3 minutes
Switch from sleep to arm.
Example 2:
Press the test button and then arm.
When the Sensor detects motion 2 times in 3 minutes it will automatically enter into
power saving mode. When no movement is detected in the next 3 minutes the Sensor
will re-set to working mode. During the 3 minute power saving the Sensor will not be
active and will not send a signal to the Control Panel.
Detection Range
Top view
Side view
2.2m
Pet-Immune Function
The Sensor is designed to improve detection accuracy. Pets less than 25kgs will not
trigger the alarm.
2-2.2m
1m
8m
2-2.2m
Sensor Zone Modes
Sensors can be assigned to different zones for different requirements, there are four
different zone types:
Normal Zone
:
In
Arm
or
Home Arm Mode
, the Sensors set to normal zone work
normally. Once intrusion is detected, the Sensors will trigger an alarm.
Home Zone:
When the system is in Home Arm (Part Arm) state the Sensors set to
Home Zone
are disarmed. The Sensors set to other zones are armed. This is known as,
Part Arm.
Single Delay Zone:
Sensors set to this zone will alarm at the specified time (which can
be set in
the
Entry Delay
setting) after being triggered.
24-H Zone:
Sensors set to 24-H Zone trigger an alarm immediately when intrusion is
detected both when the system is armed or disarmed.
Sensors
Zone Mode (Default Settin
g)
Door/Window Sensor
Normal Zone
PIR Motion Sensor
Home Zone
You can set the zone assigned to the Sensor by changing the array of the jumpers inside
the Sensor. After changing the zone setting the Sensor must be re-paired to the Control
Panel.
Note:
any movement within the 3 minutes will extend power saving mode by another 3 minutes
Example 1:
Initial start and then arm